Apera Available

Value Series Benchtop pH Meter Kit

Lab-grade pH accuracy with a refillable electrode and 200-point data logging — built for daily production use.

The Apera PH910 (AI5610) Value Series Benchtop pH Meter Kit delivers ±0.01 pH accuracy powered by the LabSen 211 refillable glass electrode and a dedicated temperature probe — giving commercial cultivators a station-grade measurement tool without sacrificing simplicity. A 200-set manual/auto data logger with USB output keeps your nutrient-solution records organized and audit-ready.

±0.01 pH ±1 digit
pH Accuracy
0.00–14.00 pH
pH Range
200 sets / USB out
Data Logger
0–100°C (Auto/Manual)
Temp Compensation

What It Is

The Apera PH910 is a value-tier benchtop pH meter designed for lab-grade measurement of general water solutions. It ships as a complete kit: the PH910 meter unit, a LabSen 211 refillable glass pH combination electrode, a separate MP500 temperature probe, a flexible electrode holder, a 9V power adapter, 50 mL pH buffer solutions (4.00, 7.00, 10.01), and an instruction manual. Everything you need to calibrate and start taking production-quality readings is in the box.

The meter reads on a large TFT HD color display that shows pH value, temperature, electrode slope, calibration buffer indicators, and datalogger status simultaneously. A smiley-face stability icon confirms when a reading has locked — no guesswork about whether the probe has settled. The operating system supports English, German, Spanish, and Mandarin with on-screen graphic tutorials, which matters on a production floor where not every grower is reading from the same manual.

Who It's Built For

Any licensed cannabis or hemp operation running nutrient solutions — coco, rockwool, DWC, NFT, flood-and-drain — needs a reliable pH station at the mixing bench. Pocket testers are useful for spot checks in the canopy, but they drift faster and their electrodes are harder to maintain. A dedicated benchtop unit with a refillable glass electrode and a separate temperature probe is what you want at the point where fertigation solutions are actually prepared.

The PH910 is particularly well-suited to mid-size and larger production facilities that mix multiple tanks per day, run multiple cultivars with different target pH windows, or that operate under state compliance frameworks requiring documented water-chemistry records. The 200-set data logger with USB export gives you a structured log you can pull into a spreadsheet without transcribing handwritten numbers. Multi-site operators can standardize on one meter model across locations and share calibration protocols without retraining staff.

Key Features

The LabSen 211 electrode is a refillable glass combination electrode built on Swiss sensor materials with a low-impedance glass membrane and a long-life reference system. Refillable construction means you can replenish the electrolyte and extend electrode service life rather than replacing the probe every few months — a meaningful cost difference in a high-frequency testing environment. The separate MP500 temperature probe provides independent ATC over the full 0–100°C range.

Calibration supports 1 to 3 points with automatic buffer recognition across five standard solutions (1.68 / 4.00 / 7.00 / 10.01 / 12.45). The smart self-diagnosis system flags calibration issues before they corrupt readings, and the electrode slope is displayed immediately after each calibration cycle so you can assess probe health without running secondary verification steps. Buffer standard sets span USA, NIST, and CH standards, plus user-defined inputs. The standard BNC pH connector and RCA temperature connector (NTC 30KΩ) make the unit compatible with the full Swiss LabSen electrode lineup if you need to swap in a specialty probe for a different sample type.

How It Fits a Commercial Build

At the mixing station, the PH910 sits on the bench, plugged into a standard 120V outlet, with the electrode holder keeping the LabSen 211 positioned cleanly between measurements. Because pH and temperature read simultaneously from a single measurement event (electrode + dedicated temp probe), you get a full ATC-corrected reading without a separate thermometer step. For operations calibrating once per shift, the 3-point auto calibration takes under two minutes with automatic buffer recognition.

The USB data output integrates directly with standard record-keeping workflows — export the 200-record log to a computer, append to your batch records, and you have a timestamped pH history for every tank you mixed. For facilities under state track-and-trace or internal SOP documentation requirements, this replaces a manual logbook without requiring proprietary software. The 3-year instrument warranty and 6-month probe warranty reflect Apera's standard commercial coverage; replacement LabSen 211 electrodes are stocked and orderable through HSC when the time comes.

Specifications

pH Measuring Range0.00–14.00 pH
pH Resolution0.1 / 0.01 pH (selectable)
pH Accuracy±0.01 pH ±1 digit
Temperature Compensation Range0–100°C, Auto (ATC) or Manual (MTC)
Temperature Accuracy±0.5°C ±1 digit
Calibration Points1–3 points, auto buffer recognition (1.68 / 4.00 / 7.00 / 10.01 / 12.45 pH)
Data Logger200 sets, manual/auto; USB data output
pH ElectrodeLabSen 211 refillable glass combination electrode (BNC connector)
Temperature ProbeMP500 (RCA connector, NTC 30KΩ thermistor)
DisplayLarge TFT HD color screen, multi-language (EN / DE / ES / ZH)
Power9V adapter, 120V / 60Hz
Warranty3 years (instrument) / 6 months (probe)

Frequently Asked Questions

What's the difference between the PH910 and a standard pocket pH pen?

The PH910 is a mains-powered benchtop unit with a separate temperature probe for true ATC, a refillable glass electrode that lasts longer and maintains accuracy better under frequent use, a 200-set data logger, and a USB export port. Pocket pens are useful for canopy spot-checks but are not designed for the measurement frequency or documentation requirements of a production mixing station.

How often does the LabSen 211 electrode need to be replaced?

Electrode lifespan depends on measurement frequency, sample chemistry, and maintenance discipline. Apera generally recommends replacing glass electrodes after roughly one year of frequent use. Because the LabSen 211 is refillable, you can extend its service life by replenishing the electrolyte and storing the electrode properly in 3M KCl solution between uses. HSC can supply replacement LabSen 211 electrodes when needed.

Does the PH910 support three-point calibration, and which buffer standards does it recognize?

Yes. The PH910 supports 1 to 3 point automatic calibration with automatic buffer recognition across five standard values: 1.68, 4.00, 7.00, 10.01, and 12.45 pH. It supports USA, NIST, and CH buffer series, plus user-defined standards. After calibration, the electrode slope is displayed on screen so you can immediately assess whether the probe is performing within spec.

Can I use a different pH electrode with the PH910 if I need to test a different media type?

Yes. The PH910 uses a standard BNC pH connector and an RCA temperature connector (NTC 30KΩ), making it compatible with the full Apera Swiss LabSen electrode lineup. If your operation tests media with high protein, sulfide, or viscous samples, specialty LabSen electrodes are available as add-ons.

How does the USB data export work, and is proprietary software required?

The PH910 logs up to 200 measurement sets in its internal memory (manual or auto logging). The USB port transfers that log to a connected computer. Apera provides optional PC-Link software for the 910 series, but the raw data export can also be accessed without it, allowing import into standard spreadsheet applications for batch documentation or compliance records.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote