Genuine replacement 4-in-1 climate sensor purpose-built for the TrolMaster Green-X (GCS-1) system.
The TrolMaster MBS-GH is the OEM 4-in-1 environmental sensor for the Green-X GCS-1 greenhouse control system, simultaneously monitoring air temperature, relative humidity, CO2 PPM, and ambient light for day/night mode detection — all over a single RJ12 connection.
The MBS-GH is TrolMaster's dedicated 4-in-1 environmental sensor for the Green-X greenhouse control platform. In a single housing it reads four parameters: air temperature, relative humidity, CO2 concentration in parts per million, and a photocell that signals the GCS-1 controller whether the space is in day or night mode. All four data streams feed the controller simultaneously over the standard TrolMaster RJ12 bus, keeping wiring simple in a production greenhouse.
Every GCS-1 Green-X controller ships with one MBS-GH included. This listing is the standalone replacement unit — the part you need when a sensor reaches end of life, is damaged, or when you're adding a second controller set to an expanded zone that requires its own dedicated sensor node.
The GCS-1 is designed for licensed greenhouse operations running irrigation, climate, CO2, lighting, and curtain/vent motor control under one modular system. The MBS-GH is the primary indoor environment input for that controller — without it, the GCS-1 has no source for temperature, humidity, or CO2 data and cannot execute climate-based automation logic.
For facilities running multiple GCS-1 zones — separate bays, separate houses, phased expansions — each controller set requires its own MBS-GH. The sensor connects to the RJ12 SENSORS port on the bottom of the GCS-1 unit. Additional sensors (weather station MBS-WS, quantum sensor MBS-PAR, smoke detector MBS-SD) connect alongside it and extend the system's monitoring capability without replacing the MBS-GH's core climate role.
The Green-X platform also supports up to 10 DS-type plug-in device modules, 96 scheduled irrigation outputs, and integration with curtain motor controllers — all of which rely on accurate MBS-GH readings to trigger properly.
Four parameters in one probe means fewer penetrations through grow walls or ceiling panels, less cabling, and a single failure point to monitor rather than four separate sensors. The integrated photocell handles automatic day/night mode switching in the GCS-1 without requiring a separate light sensor or manual schedule override — useful in greenhouse environments where natural light and supplemental lighting interact.
CO2 monitoring through the MBS-GH feeds directly into the GCS-1's climate logic, allowing the system to manage supplemental CO2 delivery in response to real measured PPM rather than a timer. Paired with the GCS-1's data logging capability and the free TrolMaster mobile app, operators get historical trend data on all four parameters — useful for compliance documentation, crop steering records, and identifying environmental drift between inspection cycles.
The plug-and-play RJ12 connection means field replacement requires no re-configuration of the controller. Swap the sensor, reconnect the cable, and the GCS-1 resumes reading from the new unit.
The MBS-GH is exclusively designed for the TrolMaster Green-X (GCS-1) control system. It is not interchangeable with TrolMaster Hydro-X (HCS-series) sensors such as the MBS-PRO or MBS-TH, and it is not compatible with the Carbon-X (CDA-1) platform. If you run Hydro-X controllers, the correct 4-in-1 sensor for that system is the MBS-PRO.
The GCS-1 supports a maximum of one MBS-GH per controller set. If your greenhouse requires monitoring of outdoor conditions alongside indoor data, the MBS-WS weather station sensor handles outdoor temp, humidity, wind speed, and rainfall and connects separately to the GCS-1 alongside the MBS-GH. HSC carries the full TrolMaster Green-X sensor and accessory lineup — contact us to spec out a complete system or replace individual components.
| SKU | MBS-GH |
| Brand | TrolMaster |
| Compatible Controller | Green-X Greenhouse Control System (GCS-1) |
| Parameters Measured | Air Temperature, Relative Humidity, CO2 PPM, Photocell (Day/Night) |
| Connection Interface | RJ12 |
| Max Units per GCS-1 | 1 per controller set |
| Application | Greenhouse / Indoor Cultivation Climate Monitoring |
| Controller Operating Temp Range (GCS-1 system) | 32–122°F (0–50°C) |
| Controller Operating Humidity (GCS-1 system) | 5–95% RH |
| Sensor Type | Replacement / Standalone (not bundled with GCS-1) |
No. The MBS-GH is designed exclusively for the TrolMaster Green-X (GCS-1) greenhouse control system. Hydro-X (HCS-1, HCS-2, HCS-3) controllers use the MBS-PRO or MBS-TH sensor family. Using the wrong sensor with the wrong controller platform will result in no data output.
The GCS-1 Green-X controller includes one MBS-GH sensor as part of its standard package. The MBS-GH listed here is the standalone replacement unit — for operators who need to replace a failed or damaged sensor, or who are adding a second GCS-1 controller to an additional zone.
No. The GCS-1 supports a maximum of one MBS-GH per controller set. For facilities with multiple zones or greenhouse bays requiring independent climate monitoring, each zone needs its own GCS-1 controller paired with its own MBS-GH.
The integrated photocell in the MBS-GH detects ambient light levels to determine day vs. night mode for the GCS-1 controller. This allows the system to automatically shift between day and night control parameters — such as temperature setpoints or CO2 targets — without requiring a manually programmed light schedule.
No. The MBS-GH uses a plug-and-play RJ12 connection. Replacing the sensor is a straightforward cable swap — disconnect the old sensor from the SENSORS port on the GCS-1, connect the new MBS-GH, and the controller will resume reading environmental data immediately with no reprogramming required.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote