OEM 400W DE HPS lamp for Matrix Hybrid and compatible double-ended fixtures.
Matrix DE HPS 400W Lamp (SKU 10-010201-025) is the factory replacement double-ended HPS lamp for Matrix Hybrid 1000W and other Matrix DE fixture platforms. Like all HPS lamps, output degrades progressively over rated life — commercial operators replace on a set hour schedule, not at failure, to protect yield consistency.
The Matrix DE HPS 400W is the factory-spec double-ended high-pressure sodium lamp used in Matrix's Hybrid 1000W fixture — the 400W HPS channel that delivers the red-dominant spectrum and radiant heat that the Hybrid platform is built around. It is also compatible with other Matrix DE fixture platforms that accept a 400W DE HPS lamp.
Double-ended HPS lamps connect at both ends of the arc tube rather than through a single mogul base. That two-point connection allows the arc tube to operate at higher internal temperatures, which increases photon output and maintains spectral stability more consistently over the lamp's life compared to single-ended HPS. The 2100K color temperature places this lamp's output deep into the red and orange spectrum — the range most relevant to flowering-stage photosynthesis and flower development.
This is a consumable part. Rated life is approximately 10,000 hours, but lumen output degrades before that threshold is reached. In commercial flowering rooms running 12-hour photoperiods, operators should track lamp hours and replace on a defined schedule rather than waiting for visible failure.
This lamp is specifically for operators running Matrix Hybrid 1000W fixtures or other Matrix DE platforms that use the 400W double-ended HPS channel. It is not a universal DE lamp — DE HPS compatibility is format-specific and operators should confirm fixture compatibility before ordering any DE replacement lamp.
The typical buyer is a licensed cannabis or hemp cultivation operation that runs Matrix Hybrid fixtures across a flowering room and needs to maintain a standing supply of replacement lamps for scheduled changeouts. High-canopy commercial rooms running multiple fixtures will turn lamps over on a regular cycle; having replacement stock on hand prevents unplanned downtime during a flowering run.
Multi-site operators and master growers managing several rooms are the primary audience. One-off lamp failures mid-cycle are disruptive — the correct approach is a fixed replacement interval (tracked in a grow room log) so lamps are swapped proactively, during a dark period, before output has degraded to a level that affects yield.
HPS lamps — single-ended and double-ended alike — do not fail sharply. Output falls gradually as the arc tube ages. By the time a lamp reaches its rated hour threshold, lumen output has typically declined 20–30% from initial values. In a tight flowering room where PPFD targets are dialed, that depreciation directly affects canopy density and bud weight across later cycles.
The DE format maintains output more consistently over lamp life compared to single-ended HPS, but depreciation still occurs. Commercial standard practice is to replace DE HPS lamps at or before 10,000 hours. At a 12-hour flowering photoperiod that works out to roughly 2.3 years of continuous use — but many commercial operations replace on shorter intervals (annual or seasonal) to keep PPFD targets consistent across all zones.
Tracking lamp hours per fixture in a grow room log is the simplest way to manage this. Stagger changeouts across rooms rather than replacing all lamps simultaneously to avoid sudden whole-facility output changes.
SKU 10-010201-025 is the Matrix-specified replacement lamp for the 400W DE HPS channel. Always verify that your fixture platform accepts a 400W DE HPS lamp — the Matrix Hybrid 1000W uses a 400W DE HPS as one of its three light sources (alongside the 560W LED and 40W far-red channel), and this lamp is the correct field-replacement for that HPS channel.
DE HPS lamps require DE-specific fixture hardware. This lamp will not fit single-ended (mogul base) reflectors or ballasts. If you are ordering for a Matrix DE 1000W fixture — which ships with a 1000W DE HPS lamp — confirm whether you need the 400W or 1000W replacement before submitting a quote request.
HSC supplies this lamp as a consumable accessory to commercial accounts running Matrix fixture platforms nationwide. Request a quote for unit pricing on single lamps or case quantities for scheduled facility-wide changeouts.
| SKU | 10-010201-025 |
| Brand | Matrix |
| Lamp Type | High-Pressure Sodium (HPS) |
| Configuration | Double-Ended (DE) |
| Wattage | 400W |
| Color Temperature (CCT) | 2100K |
| Rated Life | ~10,000 hours |
| Spectrum Character | Red / orange dominant — optimized for flowering stage |
| Compatible Fixtures | Matrix Hybrid 1000W (HPS channel), Matrix DE platforms accepting 400W DE HPS |
| Replacement Type | Consumable — schedule-based replacement recommended |
This lamp is the factory-specified replacement for the 400W HPS channel in the Matrix Hybrid 1000W fixture. It is also compatible with other Matrix DE platforms designed for a 400W double-ended HPS lamp. Always confirm your fixture's lamp spec before ordering — the Matrix DE 1000W fixture uses a 1000W DE HPS lamp, not a 400W.
DE HPS lamps are rated to approximately 10,000 hours, but lumen output typically drops 20–30% before that threshold. At a 12-hour flowering photoperiod, 10,000 hours equals roughly 2.3 years of use. Most commercial operators replace on an annual or seasonal schedule — before measurable output decline affects yield — rather than waiting for lamp failure. Track hours in a grow log and replace proactively.
DE HPS ballast and lamp compatibility requires more care than single-ended HPS. DE ballasts from different manufacturers can have slightly different electrical characteristics, and off-brand lamps may not perform to spec in a matched Matrix fixture. Using the Matrix-specified OEM lamp (this SKU) is the safest approach for maintaining output and protecting the fixture's ballast.
This listing covers the single-lamp SKU (10-010201-025). If you need case quantities for a scheduled facility-wide changeout across multiple fixtures, request a quote and specify the quantity — HSC can accommodate commercial volume orders.
No. Double-ended HPS lamps require a DE-specific fixture. They connect at both ends and are not compatible with single-ended mogul-base reflectors or ballasts. If your current infrastructure is single-ended HPS, you would need to upgrade to a DE-compatible fixture before using this lamp.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote