Matrix Available

Matrix 277V 10ft right-angle M19 power cord

277V, right-angle M19 connector, 10ft — matched for Matrix M-series bar fixtures.

Matrix's 277V 10ft right-angle M19 power cord (SKU 10-010704-297) is the purpose-built connection between your 277V facility circuit and Matrix M-series LED bar fixtures that require the right-angle M19 connector. Match cord voltage to your service voltage and confirm your fixture takes the right-angle connector before ordering.

277V
Voltage
10 ft
Cord Length
Right-Angle M19
Fixture Connector
10-010704-297
SKU

What This Cord Is

This is Matrix's OEM 10-foot power cord terminated with a right-angle M19 connector on the fixture end, rated for 277V service. Matrix sells power cords separately from their fixtures — this is by design, allowing operators to match the cord to the service voltage already present in their facility rather than being locked into a single voltage configuration at the fixture level.

The right-angle M19 connector is specific to Matrix's M-series LED bar fixtures, including the M Dyna 2-Channel and M Dyna 4-Channel lines. It is a distinct connector orientation from the straight M19 cord used on the Matrix Hybrid 1000W and DE HID fixtures. Ordering the correct orientation matters: a straight cord will not seat the same way as a right-angle cord at the fixture inlet, and mixing them up at scale creates installation problems. Verify your fixture's required connector orientation before placing your order.

Where 277V Fits in a Commercial Cultivation Facility

277V single-phase power is a standard voltage in North American commercial and industrial electrical distribution. It is derived from 480V three-phase systems — the phase-to-neutral voltage on a 480V wye system is 277V. Large-scale licensed cannabis and hemp cultivation facilities routinely run 277V circuits for lighting loads because higher voltage means lower current draw at the same wattage, which translates to smaller wire gauge, lower resistive losses over long runs, and reduced panel ampacity requirements.

If your facility's lighting panels are wired for 277V — which is common in purpose-built cultivation buildings and converted industrial or greenhouse structures — this is the correct cord voltage. If your circuits are 120V or 240V, Matrix offers those variants separately. Running a 277V-rated cord on a 120V or 240V circuit, or vice versa, is an electrical hazard and will void any equipment warranty. Confirm your service voltage at the panel before selecting a cord.

Right-Angle vs. Straight M19 — Choosing the Right Connector

Matrix uses the M19 connector family across multiple fixture lines, but in two distinct orientations: straight and right-angle. The right-angle M19 — used on this cord — is specified for Matrix M-series LED bar fixtures, including the M Dyna 2-Channel (M6 645W and M8 860W) and comparable M-series configurations. The straight M19 is specified for the Matrix Hybrid 1000W and Matrix DE 1000W HID fixtures.

The right-angle orientation is practical in overhead bar-fixture installations where the cord exits perpendicular to the fixture body, keeping the cable profile lower and reducing stress on the connector at the fixture inlet. In dense canopy configurations with tight row spacing or on vertical rack tiers where overhead clearance is limited, the right-angle exit also simplifies cable management. If you are unsure which connector your fixture requires, check the fixture's accessory documentation or contact us directly — we can confirm compatibility before the order ships.

Ordering for a Multi-Fixture Room Build

Because Matrix fixtures ship without a power cord included, every fixture in a room build requires a dedicated cord ordered separately. For a room running 277V service with M-series bar fixtures, every fixture needs one SKU 10-010704-297. Account for your total fixture count when placing the cord order — staggered cord deliveries against a tight installation schedule create unnecessary delays.

If your facility runs a mix of voltages across rooms or tiers — for example, 240V in an older wing and 277V in a newer build-out — order cord voltage by room or circuit, not by fixture model. The fixture itself may be voltage-flexible (many Matrix M-series bars accept 120–277V input), but the cord must match the circuit voltage at the wall. Keep one or two spare cords on the shelf per room as insurance against damage during installation or maintenance cycles.

Specifications

SKU10-010704-297
BrandMatrix
Voltage Rating277V
Cord Length10 ft
Fixture ConnectorRight-Angle M19
Compatible Fixture LinesMatrix M-series LED bar fixtures (M Dyna 2-Channel, M Dyna 4-Channel, and compatible M-series bars requiring right-angle M19)
SoldIndividually
Included with FixtureNo — sold separately

Frequently Asked Questions

What is the difference between the right-angle M19 cord and the straight M19 cord?

The connector orientation at the fixture end differs. The right-angle M19 (this cord) is specified for Matrix M-series LED bar fixtures such as the M Dyna 2-Channel and M Dyna 4-Channel. The straight M19 is specified for the Matrix Hybrid 1000W and Matrix DE 1000W HID fixtures. Using the wrong orientation can prevent a proper seat at the fixture inlet. Check your fixture's accessory documentation or ask us to confirm before ordering.

Does this cord come included with the Matrix M Dyna fixture?

No. Matrix ships their fixtures without a power cord. The cord must be ordered separately. You need one cord per fixture, matched to your facility's service voltage (120V, 240V, or 277V) and the correct M19 connector orientation for your fixture model.

How do I know if my facility runs 277V?

277V is the phase-to-neutral voltage on a 480V three-phase wye system, common in commercial and industrial buildings. Check the voltage rating on your lighting circuit breakers or panel schedule. If you have a 480V three-phase service and your lighting circuits are wired phase-to-neutral, they are almost certainly 277V. When in doubt, have your electrician or electrical contractor confirm before you order cords.

Can I use this 277V cord on a 240V circuit?

No. A 277V-rated cord should only be used on a 277V circuit. Using it on a different voltage is an electrical hazard, may damage the fixture or driver, and will void the warranty. Matrix offers separate cord SKUs for 120V and 240V service. Select the cord that matches the circuit voltage at your wall outlet or whip.

How many cords should I order for a full room build?

One cord per fixture. If you are building or retrofitting a room with 30 M-series bar fixtures running on 277V circuits, you need 30 of this cord. We recommend ordering a small buffer — one or two extras per room — to have on hand in case of damage during installation or future maintenance. Request a quote and specify your fixture count and we will confirm the order quantity.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote