Dual-channel ThinkGrow LED integration for TrolMaster Hydro-X — full spectrum and deep red, independently scheduled.
The TrolMaster LMA-T is the dedicated lighting control adapter for integrating ThinkGrow LED fixtures into the TrolMaster Hydro-X environment control system. It bridges the Hydro-X controller's two lighting channels to ThinkGrow's proprietary low-voltage protocol, enabling independent scheduling and dimming of both the full-spectrum and deep-red output channels across up to 256 fixtures from a single adapter.
The LMA-T is a purpose-built adapter that allows the TrolMaster Hydro-X environmental control system to communicate with ThinkGrow LED fixtures using ThinkGrow's proprietary low-voltage control protocol. Most grow light manufacturers use low-volt control for dimming and scheduling, but that control takes different forms depending on the brand. The LMA-T translates the Hydro-X controller's output into the specific signal ThinkGrow fixtures expect — something a generic 0-10V adapter cannot do.
The adapter occupies both lighting control ports (Line 1 and Line 2) on the Hydro-X controller, dedicating each line to a separate spectrum channel on the ThinkGrow fixture. This gives the operator independent on/off scheduling and dimming setpoints for the full-spectrum channel and the deep-red channel from a single Hydro-X interface — no separate controller, no manual adjustments at the fixture.
Any licensed cannabis or hemp operation running ThinkGrow LED fixtures alongside a TrolMaster Hydro-X system (HCS-1, HCS-2 Pro, or HCS-3 Plus) needs the LMA-T to enable full dimming and scheduling control. Without it, the Hydro-X cannot communicate with ThinkGrow's control protocol, and the lights revert to manual dimmer adjustment at the fixture level — which is not practical at commercial scale.
This adapter is especially relevant for operators running the ThinkGrow PLUS series, where the HCS-2 and HCS-3 paired with the LMA-T can provide individual control across up to four distinct spectrum channels. Facilities scaling canopy that need repeatable, programmable light recipes across multiple flowering rooms will find the LMA-T a required component rather than an optional one.
Installation follows the standard TrolMaster plug-and-play architecture. The LMA-T connects directly to the lighting control ports Line 1 and Line 2 on the Hydro-X controller using RJ12 connections. From the adapter, ThinkGrow fixtures are chained together in a daisy-chain configuration using RJ-type lighting control cables — no proprietary wiring harnesses, no terminal blocks.
A converter cable is included in the box to bridge from the RJ12 standard to ThinkGrow's threaded waterproof connector format. For facilities with ThinkGrow fixtures using the 4-pin IP65 threaded connector, the companion ECS-9 cable (12 ft, RJ12 to 4-pin IP65) is the correct interconnect. Each LMA-T supports up to 256 ThinkGrow fixtures in a single daisy chain, making it viable for large-format commercial grows without adding additional adapters.
In a fully integrated Hydro-X build, the LMA-T slots into the lighting control layer alongside the environmental sensors, CO2 controllers, HVAC stations, and humidity management modules that the Hydro-X manages. The Hydro-X controller's free mobile app gives operators remote access to lighting schedules and dimming setpoints, so adjustments to both the full-spectrum and deep-red channels can be made off-site without touching the fixture.
For operators running the HCS-3 Plus, the LMA-T enables spectrum-level control that mirrors the granular recipe management larger facilities require — adjusting deep-red supplementation independently from broadband output during different growth phases. The entire LMA-T connection is passive once configured, with no active components at the fixture level beyond the ThinkGrow unit itself. If you are building out a new facility with ThinkGrow lighting and a TrolMaster backbone, the LMA-T is a line-item requirement at the spec stage.
| SKU | LMA-T |
| Compatible Fixtures | ThinkGrow LED series (including PLUS series) |
| Compatible Controllers | TrolMaster Hydro-X HCS-1, HCS-2 Pro, HCS-3 Plus |
| Control Channels | 2 (Line 1: Full Spectrum / Line 2: Deep Red) |
| Max Fixtures per Adapter | 256 ThinkGrow LEDs |
| Controller Connection | RJ12 (connects to lighting control ports Line 1 & Line 2) |
| Fixture Connection | RJ12 to waterproof connector (converter cable included) |
| Fixture Wiring Topology | Daisy-chain (plug-and-play) |
| Package Weight | 2.12 oz / 60 g |
| Control Functions | Independent on/off scheduling and dimming per channel |
The LMA-T is designed for ThinkGrow LED systems broadly, with the best functionality on the ThinkGrow PLUS series, where paired with an HCS-2 or HCS-3 it can deliver individual control across up to four spectrum channels. Note that fixtures with two independent manual knobs for two separate bulbs cannot be controlled via the Hydro-X regardless of adapter. Confirm your specific ThinkGrow model against TrolMaster's compatibility documentation before ordering.
The LMA-T is compatible with the HCS-1 (Hydro-X), HCS-2 (Hydro-X Pro), and HCS-3 (Hydro-X Plus). It connects to the lighting control ports Line 1 and Line 2 on each of these controllers. All Hydro-X controller tiers support the dual-channel lighting architecture the LMA-T requires.
One LMA-T adapter supports up to 256 ThinkGrow LED fixtures in a daisy-chain configuration. The LMA-T uses both available lighting control lines on the HCS-1, so if you need to exceed 256 fixtures or require separate zone control, consult TrolMaster's documentation on multi-controller or multi-zone setups using the HCS-2 or HCS-3.
A converter cable (RJ12 to waterproof connector) is included with the LMA-T. For ThinkGrow fixtures using the 4-pin IP65 threaded waterproof connector format, the TrolMaster ECS-9 (12 ft, RJ12 to 4-pin IP65) is the correct interconnect cable and is sold separately.
You need one LMA-T per Hydro-X controller, not per fixture. A single LMA-T adapter handles up to 256 ThinkGrow fixtures chained together from that controller. It uses both lighting control channels (Line 1 and Line 2) on the HCS-1, HCS-2, or HCS-3 — one channel per spectrum output on the ThinkGrow fixtures.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote