
Plug-and-play Hydro-X integration for Dimlux ballasts — automated dimming, no manual adjustments.
The TrolMaster LMA-12 Lighting Control Adapter D bridges your Dimlux ballasts to the TrolMaster Hydro-X controller, converting the Hydro-X digital signal to the analog voltage protocol Dimlux ballasts require. The result: centralized, automated control of on/off scheduling and dimming intensity across your entire Dimlux lighting bank from a single controller.
The LMA-12 is a dedicated interface adapter within TrolMaster's LMA (Lighting Control Adapter) series. Its job is simple but essential: it takes the digital control signal output by the Hydro-X controller and converts it to the 0–11.5V analog signal that Dimlux ballasts recognize for dimming and power management.
Without this adapter, the Hydro-X cannot communicate with Dimlux fixtures — the two systems use different low-voltage protocols. The LMA-12 closes that gap cleanly, with no additional wiring beyond the included RJ12 cable and the ballast's own interlink port. An onboard LED power indicator gives you instant visual confirmation that the adapter is powered and communicating.
Any licensed cannabis or hemp facility running Dimlux HID ballasts as part of a TrolMaster Hydro-X controlled environment. Whether you're operating a single flower room or a multi-room facility with dozens of Dimlux fixtures, the LMA-12 is the required hardware link between those two systems.
It's particularly relevant during facility buildouts or upgrades where operators are bringing a TrolMaster Hydro-X into an existing Dimlux lighting infrastructure — or speccing Dimlux fixtures into a new build where Hydro-X is the chosen controller platform. Without it, you're back to manual dimming at each ballast individually, which is impractical at any commercial scale.
Note: Dimlux fixtures with two-knob designs that allow individual control of two separate bulbs are not compatible with Hydro-X control via this adapter. Verify your specific Dimlux model before ordering.
The LMA-12 converts digital signal to analog, outputting 0–11.5V to match the Dimlux ballast's dimming input range. The included 0.6 ft RJ12 cable connects the adapter to the Hydro-X controller, while the RJ12 socket on the adapter's output side connects to the Dimlux ballast's interlink port.
Installation is plug-and-play — no programming or additional hardware required beyond the adapter itself and the Hydro-X controller assignment. An LED power indicator provides at-a-glance status confirmation. The adapter's compact form factor (156mm × 83mm × 30mm) makes it easy to position near the ballast or secure to grow room infrastructure without consuming meaningful space.
Once integrated, the Hydro-X can manage Dimlux ballast dimming level, on/off scheduling, and sensor-triggered responses — such as auto-dimming when canopy temperatures exceed a set threshold — all from the Hydro-X interface without touching individual fixtures.
In a fully integrated Hydro-X environment, lighting control is one of several systems managed from a single platform — alongside CO2, temperature, humidity, and irrigation. The LMA-12 is the piece that brings Dimlux ballasts into that unified ecosystem, so lighting doesn't remain an island of manual control in an otherwise automated room.
For multi-room facilities, each Hydro-X line port can be assigned a lighting group. If you're running multiple Dimlux units in a room, they can be daisy-chained through the interlink ports so a single LMA-12 manages the entire bank. This keeps wiring manageable and ensures all fixtures in a group respond identically to controller commands.
HSC supplies TrolMaster accessories and controllers to licensed cannabis and hemp operators nationwide. If you're building out or retrofitting a room around a Dimlux and Hydro-X pairing, contact us to confirm compatibility with your specific ballast models and to request a quote.
| SKU | LMA-12 |
| Compatible Controller | TrolMaster Hydro-X |
| Compatible Fixtures | Dimlux ballasts (single-knob models) |
| Output Voltage | 0–11.5V |
| Input Voltage | 12V |
| Maximum Current | 0.2A |
| Signal Conversion | Digital to Analog |
| Connection Type | RJ12 (cable included) |
| Included Cable Length | 0.6 ft (RJ12) |
| Operating Temperature | 32–122°F (0–50°C) |
| Operating Humidity | ≤90% RH (non-condensing) |
| Unit Dimensions | 156mm (L) × 83mm (W) × 30mm (H) |
The LMA-12 is designed for single-knob Dimlux ballasts. Two-knob Dimlux fixtures that allow individual control of two separate bulbs are not compatible with Hydro-X control via this adapter. Check your specific Dimlux model's control port configuration before ordering.
The LMA-12 includes a 0.6 ft RJ12 cable that connects it to the Hydro-X controller's line port. You'll also use the Dimlux ballast's own interlink port on the output side. No additional adapters or converters are required for a standard single-ballast setup.
Yes. Multiple Dimlux units can be connected in series (daisy-chained) through their interlink ports, allowing a single LMA-12 to manage an entire bank of Dimlux ballasts from one Hydro-X channel.
The Hydro-X outputs a digital control signal; Dimlux ballasts expect a 0–11.5V analog input for dimming. The LMA-12 performs that signal translation internally, so the Hydro-X can send dimming commands that the Dimlux ballast understands and executes correctly.
No. The LMA-12 is specific to Dimlux's control protocol. For fixtures using the standard 0-10V dimming protocol (many LEDs and some other ballasts), TrolMaster makes the LMA-14, which covers 0-10V compatible fixtures. Make sure to match the adapter to your specific fixture's dimming protocol.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote