Leizig Available

Leizig Duct kit (R32 Dehumidifier for LG508, LG880)

OEM duct adapter kit — matched specifically to the R32 variants of the Leizig LG508 and LG880.

The Leizig Duct Kit (SKU 31800020) is the factory-matched ducting solution for the Leizig LG508 and LG880 commercial dehumidifiers running R32 refrigerant. It enables those units to be installed outside the cultivation space and ducted in — keeping mechanical equipment out of the canopy environment while maintaining full moisture removal performance.

LG508 & LG880 (R32 variants only)
Compatible Units
R32
Refrigerant Type
31800020
SKU
Inlet & Outlet Transitions
Kit Contents

What This Kit Does

The Leizig Duct Kit allows the LG508 or LG880 dehumidifier to be positioned outside the grow room — in an adjacent mechanical space, hallway, or utility corridor — and ducted into the canopy zone through dedicated supply and return runs. Without a duct kit, the unit must sit inside the room, consuming floor space and adding heat load directly at canopy level. With this kit installed, the dehumidifier's blower pulls humid room air through a dedicated inlet duct, processes it across the refrigerant coil, and returns dry air via a separate supply duct — all without the chassis occupying grow floor or canopy airspace.

This is the OEM kit engineered specifically for the LG508 and LG880 chassis. The transitions are dimensioned to the exact port geometry of those two units. Third-party duct adapters or field-fabricated transitions introduce fit issues, air bypass, and potential static pressure increases that reduce effective CFM — avoid them on units running at 1,500 CFM (LG508) or 2,250 CFM (LG880).

Compatibility — Verify Your Refrigerant Variant Before Ordering

This duct kit is designated for the R32 refrigerant variants of the LG508 and LG880. Leizig offers the LG508 in both R410A (240V) and R32 configurations; the LG880 is available in corresponding variants as well. The chassis port geometry may differ between refrigerant builds, so model-to-kit matching is not interchangeable. Check the unit's serial label or original order documentation to confirm the refrigerant type before placing an order for this kit.

If you're specifying a new LG508 or LG880 and already know you'll be ducting the unit out of the grow room, plan the duct kit into the original order. Retrofitting ducting to an installed, operational unit is possible but requires downtime for repositioning and duct rough-in. The cleaner path is to coordinate the unit placement, structural rough-in, and duct kit installation before commissioning.

Why Duct a Commercial Dehumidifier Out of the Grow Room

High-capacity commercial dehumidifiers generate meaningful heat as a byproduct of the refrigeration cycle. The LG508 produces approximately 15,200 BTU/h of heat load; the LG880 produces approximately 22,000 BTU/h. In a sealed room, that heat load adds directly to your HVAC burden during lights-on periods. Positioning the unit in a remote mechanical space and ducting it in removes that heat load from the cultivation environment entirely — the waste heat discharges into the mechanical space rather than back into the canopy.

Remote installation also reduces in-room noise. Both the LG508 and LG880 are engineered for low-vibration operation, but any electromechanical unit running 24 hours adds ambient noise to the grow environment. Placing the chassis outside the room and running duct to the cultivation space keeps operational noise largely contained to the mechanical corridor. For multi-room facilities with centralized mechanical rooms, this approach also simplifies filter access and routine service without entering active grow spaces during the photoperiod.

Fitting This Into a Commercial Cultivation Build

The LG508 and LG880 support four mounting configurations — ceiling-suspended, wall-mounted, floor cabinet, and freestanding — and ducted remote installation is a natural extension of the ceiling-suspended or wall-mounted approach. When laying out mechanical rough-in for a new build or retrofit, plan dedicated inlet and supply duct runs sized to match the unit's blower output. The LG508 moves 1,500 CFM; the LG880 moves 2,250 CFM. Duct sizing, static pressure, and run length all affect delivered CFM at the room — design the duct system to minimize restrictions.

Both the LG508 and LG880 include RS485 (MODBUS) connectivity and remote dry contact input, so they can be integrated with your environmental controller regardless of where the chassis is physically located. Drainage still requires a gravity drain line or condensate pump routed from the unit's 3/4-inch NPT drain connection to an appropriate floor drain. Coordinate mechanical, electrical, and drainage rough-in concurrently — the duct kit handles the air path, but the full installation plan includes power, controls, and condensate management.

Contact HSC to confirm compatibility with your specific unit variant and to coordinate the duct kit alongside any LG508 or LG880 order.

Specifications

SKU31800020
Compatible ModelsLeizig LG508 (R32 variant), Leizig LG880 (R32 variant)
Refrigerant TypeR32
Kit FunctionInlet and outlet duct transitions for remote/external unit installation
LG508 Blower Output1,500 CFM @ 0.0" WG
LG880 Blower Output2,250 CFM @ 0.0" WG
LG508 Heat Load15,200 BTU/h
LG880 Heat Load22,000 BTU/h
Parent Unit FilterMERV-8/13 (31.8" × 22.3" × 1")
Parent Unit Drain Connection3/4" NPT threaded

Frequently Asked Questions

Will this duct kit work on the LG508 240V (R410A) unit?

No. This kit — SKU 31800020 — is designated for the R32 refrigerant variants of the LG508 and LG880. The LG508 is also available in a 240V R410A configuration. Confirm the refrigerant type on your unit's serial label before ordering. Contact HSC if you need help identifying your variant.

Does this kit work on any other Leizig models besides the LG508 and LG880?

No. Leizig's duct kits are model-specific. The port geometry on the LG508 and LG880 chassis differs from smaller units in the lineup. Do not attempt to use this kit on LG195, LG228, or other models — it is matched only to the LG508 and LG880 R32 variants.

How long of a duct run is practical with this setup?

Leizig does not publish a maximum duct run length in available documentation. As a general industry guideline for commercial dehumidifiers, keep total equivalent duct length as short as possible to minimize static pressure loss and maintain delivered CFM. Use properly sized, low-resistance duct and minimize elbows. Consult your mechanical contractor for site-specific duct design.

If I remote-mount the unit with this kit, can I still use the RS485 MODBUS integration?

Yes. The LG508 and LG880 include RS485 (MODBUS) connectivity and remote dry contact input regardless of physical placement. Control wiring runs from the unit chassis to your environmental controller independently of the duct installation.

How do I order this alongside a new LG508 or LG880?

Request a quote through HSC and note that you need the duct kit (SKU 31800020) alongside the dehumidifier unit. Coordinating both in a single order ensures the kit arrives ready for commissioning. HSC services licensed cannabis and hemp operators nationally.

Ready to spec this for your facility?