Leizig Available

Leizig Duct kit (R32 Dehumidifier for LG228C)

OEM duct kit engineered specifically for the Leizig LG228C — model-matched, no adapters required.

The Leizig Duct Kit (SKU 31800022) is the manufacturer-matched ducting accessory for the LG228C R32 dehumidifier, enabling targeted air distribution to specific canopy zones in sealed commercial cultivation rooms. Verify your unit model before ordering — this kit is not cross-compatible with other Leizig models.

LG228C
Compatible Unit
R32
Refrigerant (Host Unit)
228 Pints/Day
Host Unit Capacity
208–277V
Host Unit Voltage

What This Kit Is

This is the OEM duct attachment kit designed by Leizig specifically for the LG228C commercial dehumidifier — the R32 variant of their 228-pint-per-day overhead unit. It allows the LG228C's conditioned, dehumidified airstream to be channeled into ductwork rather than discharged freely into the room, giving you precise directional control over where dry air is delivered within your canopy space.

The kit is model-specific. Leizig engineers their duct accessories to interface directly with the blower housing geometry of each unit in the lineup — the LG228C variant is not interchangeable with duct kits matched to the LG195, LG335, LG508, or LG880. Confirm your unit's model number before placing an order. If you are unsure which Leizig model you have on-site, reach out to HSC and we will help you verify.

Who Needs It and Why

Standard free-discharge installation works well in smaller, well-circulated rooms where the dehumidifier's blower can move conditioned air evenly throughout the space. In larger sealed flower rooms, multi-tier vertical grows, or any facility where the unit is mounted overhead in a corner or along a perimeter wall, free discharge creates humidity gradients — zones far from the unit stay wetter than zones near it, increasing mold pressure unevenly across the canopy.

Ducted installation solves this by routing dehumidified air through a distribution run to the points in the room where moisture accumulates most heavily — typically over the canopy at mid-room and at floor level beneath benching where stagnant air collects. Operators running the LG228C in sealed rooms above roughly 1,000 square feet, or in any room with vertical racking, should strongly consider ducted deployment to maintain uniform VPD across the full canopy footprint.

Leizig LG228C — The Host Unit

The LG228C is the R32 refrigerant configuration of Leizig's 228-pint-per-day commercial dehumidifier. The LG228 line operates across 208–277V single-phase power, making it compatible with standard commercial multi-voltage panels without a dedicated transformer. At 6.9 pints per kilowatt-hour, it is an efficient unit for its capacity tier. The LG228 runs at a 68 dB(A) noise ceiling — the quietest rating in the Leizig lineup — which matters in facilities where staff work continuous shifts in the grow environment.

The LG228C uses R32 refrigerant, a chlorine-free hydrofluorocarbon with a global warming potential of 675 — approximately one-third that of R410A (GWP 2,088). This makes it the more forward-compliant refrigerant choice as federal and state regulations on high-GWP HFCs continue to tighten. The unit supports all four Leizig mounting configurations: ceiling-suspended (hoisted), wall-mounted, floor cabinet, and freestanding. Ducted operation is most commonly paired with the ceiling-suspended installation, where the unit is positioned overhead and duct runs distribute air down into the canopy zone.

Integration and Ordering Notes

Before adding this kit to your quote request, confirm that your installed or incoming unit is specifically the LG228C — the R32 variant. Leizig's LG228 line also includes 240V single-phase configurations, and duct kits are matched at the model level, not just the capacity tier. A mismatched duct kit will not seat correctly against the blower housing and will compromise both airflow performance and the structural integrity of the duct connection.

This accessory is stocked and sourced through HSC's direct Leizig account. It ships nationally to licensed cannabis and hemp facilities across the United States. If you are speccing a new LG228C installation and want to order the dehumidifier and duct kit together, request a combined quote — HSC can coordinate both items under a single order.

Specifications

SKU31800022
Compatible ModelLeizig LG228C
Refrigerant (Host Unit)R32
Host Unit Capacity228 Pints/Day
Host Unit Efficiency6.9 Pints/kWh
Host Unit Airflow520 CFM
Host Unit Voltage208–277V Single-Phase
Host Unit Operating Temp Range56–95°F
Host Unit Noise Rating68 dB(A)
Compatible Mounting ConfigurationsCeiling-Suspended, Wall-Mounted, Floor Cabinet, Freestanding

Frequently Asked Questions

Can I use this duct kit with an LG228 that is not the LG228C model?

No. Leizig duct kits are matched at the specific model level. The LG228 line includes multiple configurations — the 240V single-phase variant and the 208–277V multi-voltage variant, for example — and the C designation indicates the R32 refrigerant version. If your unit model does not specifically read LG228C, contact HSC before ordering to confirm compatibility.

Does ducting the LG228C reduce its moisture removal capacity?

Adding static pressure through ductwork can reduce blower output if the duct run is oversized, undersized, or poorly routed. For best results, size duct runs to match the unit's rated airflow (520 CFM at 0.0" WG) and keep runs as short and straight as possible. Consult your mechanical designer or HVAC contractor when planning a ducted installation in a room over 1,500 square feet.

Is this kit compatible with Leizig units that use R410A refrigerant?

This kit is matched to the LG228C, which is the R32 variant. Leizig also offers R410A configurations in the LG228 line. If your unit uses R410A, verify the full model number and contact HSC — there may be a separate duct kit matched to that variant.

What installation configurations work best with ducted deployment?

Ceiling-suspended (hoisted) installation is the most common pairing with ducted operation. The unit mounts overhead and duct runs extend horizontally or drop vertically to discharge points positioned over the canopy or along benching rows. Wall-mounted installations can also be ducted, but the orientation of the supply plenum will depend on how the unit's blower is positioned relative to the wall.

Can I order this duct kit bundled with the LG228C dehumidifier itself?

Yes. HSC supplies both the LG228C unit and its accessories through our direct Leizig account. Request a combined quote through the site and specify both items — we will coordinate them as a single order and confirm lead times for both at the time of quote.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote