Trolmaster Available

Humidistat Station, for Dehumidifier with 24V terminal

Hydro-X–integrated 24V dehumidifier control with independent Day/Night humidity setpoints.

The TrolMaster HS-1 Humidistat Station connects your commercial dehumidifier to the Hydro-X control system via its 24V low-voltage terminal, eliminating the need to switch high-amperage inrush current directly. Set independent Day and Night humidity targets and let the Hydro-X handle the rest.

24V
Output Voltage
1A Max
Maximum Current
32–122°F / ≤90% RH
Operating Environment
16ft + 4ft RJ12 Cables Included
Connectivity

What the HS-1 Does

The TrolMaster HS-1 Humidistat Station is purpose-built for one job: giving your Hydro-X controller direct, safe authority over commercial dehumidifiers that have a 24V low-voltage control terminal. Rather than cycling a dehumidifier's compressor load through a relay directly, the HS-1 operates exactly like an external humidistat wired into that low-voltage input — the dehumidifier's own internal relay handles the heavy current, and the HS-1 sends only a 24V signal to trigger it. This is the correct, manufacturer-endorsed method for integrating commercial-grade dehumidifiers into a centralized environmental control system.

On the HS-1's LCD, you can read both the current humidity reading and the active setpoint simultaneously. When connected to the Hydro-X, the controller assigns it a unique address (H1, H2, etc.) so multiple units can run on the same system daisy-chained through RJ12 cabling.

Who Needs It and Why

Commercial indoor cannabis and hemp facilities running Quest, Anden, or similar dehumidifiers with a 24V humidistat input are the primary application. If your climate control strategy calls for separate Day and Night humidity targets — tighter VPD during lights-on, relaxed setpoints during dark periods — the HS-1 handles that automatically based on photocell status fed through the Hydro-X. Without it, you're either manually adjusting the dehumidifier's onboard controls or running a basic analog humidistat with no integration into the broader environmental data your Hydro-X is logging.

Facilities that have already invested in TrolMaster's Hydro-X ecosystem get the most value here. The HS-1 extends centralized control to dehumidification without adding a separate controller or breaking out of the RJ12 device bus. It also protects electrical infrastructure by keeping the high-inrush compressor load internal to the dehumidifier, not running through an external control relay.

Key Features

LCD display shows setpoint humidity (upper) and live ambient humidity (lower) at a glance — no need to pull up an app or walk back to the controller cabinet to confirm status. The addressing system is straightforward: connect via RJ12 to the Hydro-X DEVICES port, press the addressing button, and the Hydro-X LCD confirms the assigned station ID. Up to five HS-1 units can be integrated, allowing multi-unit dehumidification arrays across large flower rooms or segmented zones to operate under unified setpoint logic.

Firmware is field-upgradeable via Micro-SD card (32GB or less), which means TrolMaster feature updates don't require hardware replacement. The plug-and-play RJ12 bus means adding or relocating a unit mid-facility build is a wiring task, not a reprogramming exercise. Wiring into the existing low-voltage thermostat terminals found on most commercial dehumidifiers means you're typically reusing conductors already run in the wall.

How It Fits Into a Commercial Build

The HS-1 slots into any TrolMaster Hydro-X environment as an expansion device on the DEVICES bus. It does not replace a temperature/humidity sensor — it's a control output node for the dehumidifier, fed set points by the Hydro-X based on the sensor data from a TSH-1 or similar station. A typical deployment: Hydro-X controller at the head, TSH-1 or equivalent sensor reading ambient conditions in the canopy zone, HS-1 wired to the dehumidifier's 24V input terminal and connected to the Hydro-X device bus via the included 16ft RJ12 cable.

For multi-room facilities or large single-room builds with zoned dehumidification, additional HS-1 units can be added to the same bus. Each receives an individual address, and the Hydro-X manages them as discrete stations. All humidity setpoints, Day/Night logic, and scheduling stay inside the Hydro-X interface — no separate app, no secondary controller, no integration overhead.

Specifications

SKUHS-1
BrandTrolMaster
Compatible SystemTrolMaster Hydro-X
Output Voltage24V
Maximum Current1A
Operating Temperature32–122°F (0–50°C)
Operating Humidity≤90% RH
DisplayLCD (setpoint + live humidity)
Firmware UpgradeMicro-SD card (≤32GB)
Package Dimensions6.2"L × 3.4"W × 3.4"H (160 × 86 × 86 mm)
In the BoxHS-1 unit, 16ft RJ12 cable, 4ft RJ12 cable, RJ12 T-splitter
Warranty3-year limited (TrolMaster)

Frequently Asked Questions

Does the HS-1 work with any commercial dehumidifier, or only specific brands?

The HS-1 is compatible with any commercial dehumidifier that has a 24V low-voltage humidistat control terminal. Most commercial-grade units — including Quest and Anden models — include this input. Check your dehumidifier's spec sheet or wiring diagram for a 24V humidistat or 'low-volt control' terminal before ordering.

How many HS-1 units can run on one Hydro-X system?

Up to five HS-1 units can be connected to a single Hydro-X controller. Each unit receives a unique address (H1 through H5) assigned via the addressing button during setup. This allows multi-unit or multi-zone dehumidification arrays under centralized control.

Do I need to run new wire to install the HS-1?

In most cases, no. The HS-1 connects to the same low-voltage wiring position where a standard external humidistat would mount. If you have existing thermostat-gauge wire run to your dehumidifier's control terminal, you can use it. The RJ12 cable included in the box handles the connection from the HS-1 back to the Hydro-X controller.

Does the HS-1 include its own humidity sensor, or does it rely on the Hydro-X sensor?

The HS-1 displays live humidity on its LCD, but humidity setpoints and day/night scheduling are managed through the Hydro-X controller, which sources sensor data from your connected environment sensors (such as a TSH-1 or similar station). The HS-1 is a control output device, not a standalone sensor/controller.

Can I update the HS-1 firmware in the field?

Yes. Firmware updates are loaded via Micro-SD card (32GB or smaller capacity). Press and hold the Addressing button while replugging the RJ12 cable and the update runs automatically. TrolMaster releases periodic firmware updates that may add features or improve compatibility.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote