Trolmaster Available

Hawkeye 3-in-1 Monitor & Logger, 3-in-1 (Temp/Humid/CO2) Sensor, Ethernet Adapter; Free Smartphone App

Standalone CO2, temp, humidity & VPD monitoring with IoT app alerts — ready out of the box.

The TrolMaster Hawkeye (CM-1) is a standalone 3-in-1 climate monitor and data logger that simultaneously tracks temperature, humidity, CO₂ (PPM), and calculated VPD in a single wall-mount unit. Ships complete with the SA-S81 remote sensor, Ethernet adapter, and DC power supply — connect it, set your thresholds, and it's working.

0–2,000 PPM
CO₂ Range
Temp / RH / CO₂ / VPD
Parameters Monitored
±30 PPM CO₂ | ±0.20°C Temp | ±7% RH
Sensor Accuracy
16 ft (SA-S81 Cable)
Remote Sensor Reach

What the CM-1 Hawkeye Does

The Hawkeye is a dedicated environmental monitor — not a controller. It does one job and does it continuously: display and log temperature, relative humidity, CO₂ PPM, and derived VPD across three dedicated LED readouts on the front panel. There are no relays, no switching circuits, and no automation outputs. That clarity is the point — it gives your facility a verified, always-on reference for climate conditions without depending on a controller's internal sensor for compliance-grade data.

The SA-S81 3-in-1 sensor attaches via a 16-foot cable, letting you position the sensor inside the canopy zone or at a regulatory-relevant measurement point while keeping the display unit outside the room for at-a-glance readings without suiting up. The unit runs on standard 100–240 VAC power and includes its DC adapter, so there's no transformer sourcing required.

Who It's For

Licensed cannabis and hemp cultivators running sealed or semi-sealed rooms will find the CM-1 most useful in two scenarios: primary monitoring for rooms that don't yet run a full TrolMaster control system, and redundant backup monitoring for rooms that do. State compliance audits and internal SOPs increasingly require documented environmental data — the Hawkeye provides that without requiring a full controller buildout.

It also fits well in mother rooms, cloning bays, dry rooms, and any ancillary space where you need verified climate data but don't need active device control. Greenhouse operators and propagation facilities running CO₂ enrichment programs use it to verify actual PPM at canopy level versus the enrichment system's own readout. Multi-site operators commonly deploy one per room as a low-cost, independent data trail alongside more complex building automation systems.

Alert System & Data Logging

Threshold alerts operate on two levels. On the unit itself, audible and visual alarms trigger whenever a measured value crosses the user-configured min or max setpoint for temperature, humidity, or CO₂. Independent limits can be set for each parameter. When the Ethernet adapter is connected and the unit is online, the TrolMaster app (iOS and Android, free) pushes the same alerts to your phone in real time — useful for facility managers who aren't on-site around the clock.

Data logging works two ways: cloud-based trend graphs through the TrolMaster app when connected to the internet, or local storage to a MicroSD card (up to 128 GB, not included) that records readings every 15 seconds in a date-stamped text file format. The MicroSD path means you retain a full local data trail even during internet outages — relevant for operations that need continuous, auditable environmental records. The unit operates fully standalone without any internet connection; connectivity adds remote visibility, not core function.

Integration & Deployment Notes

The CM-1 is part of TrolMaster's Hawkeye monitoring line and is designed to operate independently of TrolMaster's control systems (Hydro-X, Aqua-X), though both platforms use the same free TrolMaster app. If you're already running a TrolMaster controller in the room, the Hawkeye functions as a passive verification layer on a separate sensor — providing a second, independent reading from a different physical location in the canopy rather than relying solely on the controller's onboard sensor.

The unit ships ready to run: mount it, plug in the sensor, connect the DC adapter, and set your thresholds. No specialized IT infrastructure is required — the included Ethernet adapter connects to any standard network switch or router. For operations with no Ethernet run to the grow room, the CM-1 still functions fully as a local monitor and MicroSD logger; app connectivity and remote alerts simply require a live network connection. The 3-year manufacturer warranty from TrolMaster covers the unit under normal operating conditions.

Specifications

SKUCM-1
Input Voltage100–240 VAC, 50/60 Hz
Max Input Current0.6 A
Output Voltage / Current24 VDC / 0.5 A
Temperature Range0–59.0°C (32–138.2°F)
Temperature Accuracy±0.20°C
Humidity Range5–95% RH
Humidity Accuracy±7% RH
CO₂ Range0–2,000 PPM
CO₂ Accuracy±30 PPM
Working Environment0–50°C, ≤90% RH
Remote SensorSA-S81, 16 ft cable

Frequently Asked Questions

Does the CM-1 control any equipment, or is it monitoring only?

Monitoring only. The Hawkeye has no relay outputs and cannot switch or control HVAC, CO₂ systems, or any other device. It reads and logs temperature, humidity, CO₂, and VPD, and it sends alerts — that's its full scope. If you need active device control, TrolMaster's Hydro-X or Aqua-X controllers are the appropriate platform.

Does it work without an internet connection?

Yes. The CM-1 operates fully standalone without internet. The front-panel LED displays remain active, local alarms function, and if a MicroSD card is inserted, data logging continues uninterrupted. Internet connectivity is only required for TrolMaster app access and remote push notifications.

Where should I place the SA-S81 sensor relative to the canopy?

Place the SA-S81 sensor in the canopy zone where you need the most accurate climate reading — typically at or slightly above the canopy for temp/RH, or at the level where CO₂ enrichment concentrations are most critical to capture. The 16-foot cable lets you run the sensor into the room while keeping the display unit outside the door for easy monitoring without entering the space.

Can the Hawkeye CM-1 be used alongside an existing TrolMaster controller?

Yes, and this is a common deployment for commercial facilities. The CM-1 uses an independent SA-S81 sensor, so it provides a second, physically separate measurement point from the controller's sensor. Both devices feed the same TrolMaster app, giving you cross-reference visibility between control-loop readings and an independent verification sensor positioned elsewhere in the room.

What format does the MicroSD data logging use, and how do I access the records?

The unit saves readings every 15 seconds to a plain text (.txt) file named by MAC address and date, one file per day. Insert a MicroSD card (up to 128 GB capacity) into the slot on the unit, and files are written automatically. You can remove the card and read the files on any standard computer. Hot-plugging the MicroSD card while the unit is running is not recommended, as it can corrupt the files on the card.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote