OEM 277V power cord with right-angle M19 connector — matched for Flexstar fixtures on commercial 277V service.
The Flexstar 277V 10ft Right-Angle M19 Power Cord (SKU 10-010704-297) is the correct factory-matched input cord for Flexstar LED fixtures installed on 277V commercial electrical service. Match the cord to your facility's service voltage and verify the M19 connector matches your fixture's input before ordering.
This is the OEM-matched power input cord for Flexstar LED fixtures operating on 277V single-phase commercial service — the voltage delivered by one hot leg of a 480V three-phase panel, standard in commercial and industrial cultivation facilities built to NEC commercial electrical codes.
The M19 connector is a 3-pin locking-style connector used across Flexstar's commercial LED fixture line to connect the power supply enclosure (driver/ballast) to the mains feed. The right-angle configuration at the M19 end keeps the connection low-profile and directs cable routing parallel to the fixture, reducing strain on the connector body in overhead or rack-mounted installs.
At 10 feet, the cord provides enough reach for most fixture-to-breaker or fixture-to-PDU runs in standard bay spacing without requiring an extension. If your run is longer, a separate extension cord rated for 277V and M19 termination is required — do not daisy-chain standard cords to gain length.
This cord is a fit for any licensed cannabis or hemp cultivation operator running Flexstar LED fixtures on 277V service. Facilities built with 480V three-phase electrical infrastructure typically distribute 277V single-phase to individual lighting circuits — it is the most common service voltage in purpose-built commercial grow rooms, warehouses converted for cultivation, and multi-tier vertical farms.
You need this specific cord if: (1) your facility's lighting circuits are wired for 277V, (2) your Flexstar fixtures use the M19 input connector, and (3) your existing cord is damaged, missing, or you are expanding your fixture count and need additional cords to complete the install. Running the wrong voltage cord on a 277V circuit is a safety and equipment-damage risk — confirm your panel voltage before ordering.
This cord is not a universal adapter. It is voltage-specific and connector-specific. If your facility runs 120V, 208V, or 240V service, a different Flexstar cord SKU applies to your configuration.
277V is a line-to-neutral voltage derived from a 480Y/277V wye-configured three-phase service. It requires a dedicated 277V circuit with a correctly rated breaker — typically a single-pole breaker in a 480V panel. Do not attempt to connect this cord to a 120V or 240V outlet; the voltage ratings are not interchangeable.
The M19 connector mates directly to the M19 female outlet on the Flexstar power supply enclosure. Seat the connector fully and verify the lock engages before energizing. The right-angle exit keeps the cord profile tight against the fixture body, which matters in overhead installations where cable sag or tension on the connector can work connections loose over time.
For multi-fixture rows, verify whether your Flexstar configuration supports daisy-chaining via the M19 port or requires a homerun cord to each fixture. Consult the fixture-specific installation manual or contact HSC for configuration guidance before finalizing your cord count.
Facilities deploying Flexstar LEDs at scale should order cords at the same time as fixtures. Cord count equals fixture count — one cord per fixture unless your specific fixture model supports a daisy-chain topology that reduces the homerun cord count. Having spare cords on-site eliminates downtime if a cord is damaged during installation or routine maintenance.
If you are commissioning a new room or expanding canopy, confirm your panel voltage and fixture input spec with your electrical contractor before placing the cord order. Flexstar fixtures accept multiple input voltages (120V, 208V, 240V, 277V), and each voltage requires its own cord SKU. Mixing cord voltages is a code and safety violation.
Request a quote through HSC for single-unit or bulk cord quantities. HSC supplies licensed cannabis and hemp operators nationwide with Flexstar fixtures and accessories through direct vendor accounts.
| SKU | 10-010704-297 |
| Brand | Flexstar |
| Rated Voltage | 277V |
| Cord Length | 10 ft (approx. 3 m) |
| Fixture Connector | M19 3-pin (right-angle) |
| Connector Orientation | Right-angle at M19 end |
| Compatible Fixtures | Flexstar LED fixtures with M19 input connector |
| Typical Application | 277V single-phase commercial lighting circuits (480Y/277V three-phase service) |
| Category | Accessories & Cables |
This cord is rated for 277V service only. 277V is delivered as a line-to-neutral voltage from a 480Y/277V three-phase wye panel — common in commercial facilities, warehouses, and purpose-built cultivation buildings. Do not connect this cord to a 120V, 208V, or 240V circuit. If you are unsure of your panel configuration, have a licensed electrician confirm before ordering.
This cord is designed for Flexstar LED fixtures that use the M19 3-pin input connector and are configured for 277V operation. Flexstar's commercial PRO-series fixtures are multi-voltage capable (120V / 208V / 240V / 277V), and the correct cord must match both the fixture's input connector type and your facility's service voltage. Verify the M19 connector on your specific fixture model before ordering.
The right-angle exit at the M19 end directs the cable parallel to the fixture body rather than straight out from the connector face. This reduces mechanical stress on the connector in overhead or rack-mount installations where cable weight or routing tension could otherwise work a straight connector loose over time. It also keeps the cable profile lower in tight vertical spacing applications.
The M19 connector is used on Flexstar fixtures that support daisy-chain topology, but whether daisy-chaining is supported depends on the specific fixture model and driver configuration. Check your fixture's installation manual for daisy-chain guidance. For homerun installations — one cord per fixture back to the panel or PDU — order one cord per fixture.
In a standard homerun wiring configuration, you need one cord per fixture. If your specific Flexstar fixture model supports M19 daisy-chaining, the chain topology may reduce the number of homerun cords required. Confirm the wiring topology for your fixture model with HSC or the fixture installation documentation before finalizing your cord order.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.