Hard-wire Faven control runs into any 0-10V terminal block — no RJ12 port required.
The Faven RJ12 to Screw Terminal Adapter converts the RJ12 communication output from a Faven under-canopy lighting run into individual bare-wire terminals, allowing integration with any controller or dimming panel that accepts a direct analog 0-10V signal via screw connections rather than an RJ-style plug.
Faven's R-Series under-canopy fixtures (R6, R8, R8 FR) communicate over a standard analog 0-10V dimming signal carried through an RJ12 connector on the power cord communication line. Most Faven-native controllers — the Mini-Controller and compatible third-party units with RJ jacks — plug straight in. But many commercial control panels, lighting controllers, and building-management systems accept only bare-wire screw terminal inputs for their 0-10V dimming channel, with no RJ-style port at all.
This adapter bridges that gap. One end accepts the RJ12 plug from the Faven communication run; the other breaks each conductor out to an individual screw terminal, so you can land the control wires cleanly onto any terminal block. No cutting, no stripping the power cord, no improvised splices — the signal path stays intact and the connection is serviceable.
This part belongs on the spec list any time a commercial facility is integrating Faven R-Series fixtures into a control architecture that does not have a dedicated RJ12 dimming port — common scenarios include Argus, Growlink, or custom BMS panels wired to terminal blocks, multi-zone 0-10V dimmer boards, and retrofit installations where the existing lighting controller was built around screw-terminal inputs.
It is also the correct solution when facilities need to hard-wire a Faven run into a 0-10V control panel to comply with a facility's internal wiring standards — some operations require all low-voltage control wiring to terminate on documented, inspectable terminal blocks rather than modular plugs. Order one adapter per control zone that requires screw-terminal termination. Note: this adapter is designed for the analog 0-10V R-Series (R6, R8, R8 FR) and is not intended for the Faven Chroma line, which uses a separate digital RS485 protocol.
The adapter is purpose-built for Faven's communication ecosystem. The RJ12 (6-position, 6-conductor) fixture-side interface mates directly with Faven's watertight communication cables and T-splitters, so it slots into an existing daisy-chain run without disrupting the rest of the network. The screw terminal side provides individual conductor access for a clean, labeled termination at the controller.
Because Faven's R-Series uses the widely adopted 0-10V analog dimming standard — the same protocol used across TrolMaster, Argus, Growlink, and similar platforms — the adapter makes Faven fixtures compatible with virtually any commercial dimming controller that speaks 0-10V, without proprietary hardware in between. The compact form factor means it sits unobtrusively at the point of connection without adding meaningful wire management complexity.
In a typical Faven R-Series deployment, fixtures are daisy-chained along a bench run using watertight RJ12 cables and T-splitters. The communication line from the last fixture (or the first, depending on run direction) needs to reach the controller. If the controller has an RJ jack, a standard communication cable does the job. If the controller only has terminal inputs, the RJ12 to Screw Terminal Adapter goes at the end of the run — the RJ12 side connects to the cable coming off the fixture chain, and the screw terminals land on the controller's 0-10V input.
At 120V, Faven supports up to 10 fixtures per circuit; at 240V that extends to 17; at 277V up to 20. In multi-zone facilities where each zone has its own terminal-block dimming channel, one adapter per zone keeps the wiring organized and the control architecture clean. Paired with Faven's watertight T-splitters and communication cables, this adapter completes the accessory set for a fully water-protected, commercially serviceable under-canopy lighting run.
| SKU | 10-010704-349 |
| Brand | Faven |
| Fixture-Side Connector | RJ12 (6P6C, 6-position 6-conductor) |
| Controller-Side Connection | Screw terminal block |
| Control Signal Type | Analog 0-10V dimming |
| Compatible Fixture Lines | Faven R6, R8, R8 FR (R-Series) |
| Not Compatible With | Faven Chroma (Chroma uses RS485 digital protocol) |
| Application | Hard-wire Faven communication run to terminal-block dimming controllers |
| Category | Cables & Accessories — Lighting & Cultivation |
No. The Faven Chroma line uses a separate digital RS485 communication protocol and requires its own dedicated Chroma power cord and control accessories. This adapter is designed for the analog 0-10V R-Series fixtures (R6, R8, R8 FR) only. The R-Series and Chroma lines use incompatible control protocols and are not cross-compatible.
Yes, if your controller's 0-10V dimming output terminates on screw terminals rather than an RJ jack. Faven R-Series fixtures use standard 0-10V dimming, which is compatible with TrolMaster, Argus, Growlink, and similar platforms. This adapter simply converts the RJ12 communication run to bare-wire terminals so it can land on whichever terminal block your controller provides.
One adapter per control zone that requires screw-terminal termination. Each adapter handles one 0-10V dimming channel — meaning one daisy-chain run (or zone) of R-Series fixtures. If you have four independent dimming zones all terminating on a terminal-block panel, you need four adapters.
The adapter sits at the point where the Faven communication line meets the controller — the terminal end of the run. The rest of the daisy chain, including watertight cables and T-splitters, remains unchanged. The adapter itself is an open terminal-block format intended for a controller panel or enclosure, not for a wet-zone installation point.
In most cases this adapter, combined with a Faven watertight communication cable running from the fixture chain to the controller location, is all that's required. If your run spans multiple benches or branches into separate zones, Faven's T-splitters handle splitting a communication line into two branches before it reaches the adapter.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote