Faven Available

Faven 480V Power Cord BARE 1.0

Hardwire your Chroma 1.0 system to a 480V supply — no plug, no compromise.

The Faven Chroma 1.0 480V Bare-Lead Power Cord is the correct supply-side cable for Chroma 1.0 under-canopy fixtures wired to a 480V electrical infrastructure. At 10 ft / 3 m, it provides the reach needed to connect the head of a daisy-chain to a hardwired 480V circuit, terminated on-site by a licensed electrician.

480V
Rated Voltage
10 ft / 3 m
Cord Length
Bare Lead
Supply Termination
Chroma 1.0 Only
Fixture Compatibility

What This Cord Is

The Faven Chroma 1.0 480V Bare-Lead Power Cord (SKU 10-010704-215) is the supply-entry cable for Faven Chroma 1.0 under-canopy LED fixtures installed on 480V commercial electrical systems. Unlike the 120V or 240V variants that ship with molded plug connectors, this cord terminates in bare leads on the supply end — meaning a licensed electrician connects it directly to a junction box or disconnect on a 480V branch circuit. The fixture end mates with the Chroma 1.0 digital communication connector.

At 10 feet (3 meters), the cord gives installers adequate working length to route from the first fixture in a daisy-chain back to the panel-side connection point without excess slack cluttering the canopy zone. One cord is required per daisy-chain — it powers the lead fixture, and Chroma jumper cables carry the signal and power through the rest of the run.

Who It's For

This cord is the correct choice for licensed cannabis and hemp operators whose facilities run 480V three-phase or 480V single-phase branch circuits — a common infrastructure standard in purpose-built commercial cultivation buildings, converted industrial facilities, and multi-tier vertical grows where 480V distribution minimizes wire gauge requirements and reduces current draw across long conductor runs.

If your Chroma 1.0 fixtures are already specified and your electrical infrastructure is 480V, this is the only supply cord that matches. It is not interchangeable with the 120V, 240V, or 277V Chroma 1.0 cords, and it is not compatible with the Faven R6, R8, or Chroma 3.0 series. Confirm your voltage and your Chroma generation before ordering.

Chroma System Context — Cord Role in the Install

Faven Chroma fixtures use a digital communication protocol — distinct from the simple 0–10V analog dimming used by the R6 and R8 series. The Chroma 1.0 power cord carries both power and the digital control signal from the supply point into the first fixture. This is why Chroma cords are not interchangeable with R-series cords: the connector type and internal wiring differ to support that digital protocol.

Each bench or daisy-chain requires exactly one power cord at the head of the run. From there, Faven Chroma jumper cables (sold separately) link fixture to fixture. If your total fixture count per circuit exceeds the maximum daisy-chain length for your voltage, you will need a second power cord to start a new chain. For large commercial rooms with many benches, coordinate your cord count with your fixture layout — one power cord per chain, per bench segment.

Installation Notes — 480V Bare-Lead Specifics

Bare-lead cords require a licensed electrician for the supply-end connection. The bare leads are connected inside a listed enclosure — typically a junction box or dedicated disconnect — on a properly protected 480V circuit. This is standard practice for commercial horticultural lighting in facilities with 480V distribution, and this cord is designed with that workflow in mind.

Do not attempt to field-fit a plug to this cord or connect it to a voltage other than 480V. Faven's separate 120V, 240V, and 277V Chroma 1.0 cords are available for facilities on those voltage standards. If you are unsure which cord version your build requires, confirm your panel voltage and branch circuit rating with your MEP engineer or electrician before ordering.

Specifications

SKU10-010704-215
BrandFaven Lighting
Cord Length10 ft / 3 m
Rated Voltage480V
Supply TerminationBare lead (field-terminated by licensed electrician)
Fixture TerminationChroma 1.0 digital protocol connector
Compatible FixturesFaven Chroma 1.0 under-canopy LED fixtures only
CommunicationDigital protocol (powers and communicates with Chroma 1.0)
Cord RoleSupply-entry / daisy-chain head — one per chain

Frequently Asked Questions

Is this cord compatible with Faven R6 or R8 fixtures?

No. This cord is designed exclusively for Faven Chroma 1.0 fixtures. The R6 and R8 series use different power cords with a different connector type and wiring configuration. Using the wrong cord will result in a mismatched connection. Order the R-series power cord if you are running R6 or R8 fixtures.

Is this the same as the Faven Chroma 3.0 power cord?

No. Faven produces separate power cords for the Chroma 1.0 and Chroma 3.0 lines. This SKU (10-010704-215) is specific to the Chroma 1.0 at 480V. Confirm your Chroma generation before ordering — using the wrong generation cord may result in a connector mismatch.

Do I need one cord per fixture or one per bench?

One power cord per daisy-chain, not per fixture. The power cord connects the supply circuit to the first (head) fixture in a run. Subsequent fixtures in the chain are linked by Faven jumper cables, which are sold separately. If your fixture count per bench exceeds the maximum daisy-chain length for 480V, you will need an additional cord to start a second chain.

Can I connect this cord myself, or does it require an electrician?

The bare-lead supply end must be connected by a licensed electrician inside a listed enclosure on a properly protected 480V circuit. This is standard for any bare-lead commercial lighting cord. The fixture end uses a proprietary Chroma 1.0 connector and can be handled by the installation crew following Faven's installation guide.

What if my facility runs 240V or 277V instead of 480V?

Faven offers Chroma 1.0 power cords at other voltage ratings to match different electrical infrastructures. If your facility runs 120V, 240V, or 277V, request a quote for the correct voltage variant. Do not use this 480V cord on a lower-voltage circuit.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote