Replacement EC probe for Growlink batch tankLINK fertigation monitoring.
The Growlink Batch TankLINK EC Sensor is a high-precision conductivity probe designed to deliver accurate, real-time electrical conductivity measurement inside nutrient batch tanks. Purpose-built for the Growlink LINKS ecosystem, it keeps your feed recipe tight across every mix cycle.
The Growlink EC Sensor (GL-LINK-EC-SENSOR) is a dedicated conductivity probe for the Growlink LINKS batch tankLINK controller. It connects directly to the batch tankLINK's terminal block input and feeds real-time EC data into Growlink OS, giving operators continuous visibility into nutrient solution strength without manual dip-and-read checks.
This is an accessory/replacement sensor — it is not a standalone device. The batch tankLINK controller reads the probe and handles data logging, alerting, and platform communication. If your facility already runs batch tankLINK hardware and your EC probe has drifted, fouled, or failed, this is the direct replacement.
Any licensed cannabis or hemp operation running Growlink's batch tankLINK for automated nutrient mixing and tank management. That includes single-facility craft operators who built out on LINKS hardware, as well as multi-site MSOs standardizing on Growlink OS across rooms or campuses.
It's also the right add-on when expanding a Growlink installation — if a second batch tank is coming online and the new tankLINK unit ships without an EC probe, or if your current probe is out of calibration range and replacement beats recalibration labor. Commercial fertigation runs continuous EC monitoring; having a verified spare on-hand is standard operating procedure for any production facility that cannot afford a feed-recipe drift event.
The sensor is purpose-engineered for submerged, continuous-duty use in nutrient solutions — the kind of wet, chemically active environment that degrades off-spec probes quickly. It connects via the batch tankLINK's terminal block EC input, and once registered in Growlink OS, EC readings are logged alongside pH and temperature data on the controller's LCD and in the cloud dashboard.
Growlink OS stores up to 21,600 data points per sensor with graphical history, and operators can set high and low EC alarm thresholds. When the value goes out of range, on-screen and app alerts fire — so a bad mix batch or a depleting tank doesn't run undetected through a full irrigation cycle. The plug-and-play connection means swap-out time is minimal and recalibration follows Growlink's standard probe calibration workflow documented in their knowledge base.
The Growlink LINKS platform is modular by design — each device handles one job and connects into a common network managed through Growlink OS. The batch tankLINK sits in the fertigation layer of that stack, alongside valveLINK irrigation controllers, canopyLINK sensor hubs, and climaLINK environmental sensors. The EC probe is what gives the batch tankLINK its nutrient-monitoring function; without it, the controller can track pH and temperature but cannot confirm the conductivity of the mix.
For facilities running multi-tank setups, each batch tankLINK requires its own EC probe. Continuous EC monitoring through the Growlink platform closes the loop on nutrient delivery — tank EC is tracked through mixing, the data is logged per batch, and deviations trigger alerts before the solution reaches the plants. That data trail also supports the compliance and traceability documentation many licensed operators need to maintain.
| SKU | GL-LINK-EC-SENSOR |
| Compatible Controller | Growlink batch tankLINK (LINKS platform) |
| EC Measurement Range | 0–7000 µS/cm |
| EC Accuracy | ±20 µS/cm below 2000 µS/cm; ±50 µS/cm above 2000 µS/cm |
| Resolution | 2 µS/cm |
| Connection Type | Terminal block input on batch tankLINK controller |
| Platform Integration | Growlink OS (cloud dashboard + mobile app) |
| Data Logging | Up to 21,600 data points per sensor (via batch tankLINK) |
| Alarm Capability | High/low EC threshold alerts via Growlink OS |
| Made In | USA (Growlink LINKS line) |
This sensor (GL-LINK-EC-SENSOR) is designed for the Growlink LINKS batch tankLINK controller. If you're running the legacy Growlink Batch Tank Module (BTM/Smart Water platform), verify probe compatibility with Growlink support before ordering — the legacy and LINKS hardware lines use different input configurations.
Yes. The batch tankLINK kit ships with an EC probe, pH probe, and temperature probe. The GL-LINK-EC-SENSOR is the standalone EC probe — it's the direct replacement if your existing probe has fouled, drifted beyond calibration, or failed, and it's the right add-on if you're adding a second batch tank to your system.
The sensor covers 0–7000 µS/cm (0–7 dS/m), which covers the full range of standard commercial cannabis fertigation programs. Most cannabis production runs peak EC targets in the 3.5–6.0 dS/m range during late flower, well within the sensor's measurement window.
Probe service intervals depend on solution chemistry, temperature, and how aggressively the tank is run. Growlink documents the calibration procedure for EC and pH probes in their knowledge base. In high-volume commercial environments, probes typically require periodic calibration checks and replacement on a scheduled basis — keeping a spare on-hand minimizes downtime.
Yes. Once the batch tankLINK is connected to the Growlink HUB and registered in Growlink OS, EC readings from this probe are accessible through the Growlink cloud dashboard and mobile app in real time, alongside pH, temperature, and tank level data. High and low threshold alerts can be configured to notify via the app when EC goes out of the target window.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote