Trolmaster Available

Device Station Kit with 4 control outlets including 1x DST, 1x DSH and 2x DSP

Four dedicated control outlets — temperature, humidity, and timer — in one plug-and-play module for TrolMaster Tent-X systems.

The TrolMaster 4RS-2 Device Station Kit is a universal 4-outlet module that connects directly to the Tent-X controller via RJ12 cable, adding one DST (temperature), one DSH (humidity), and two DSP (timer/program) control outlets in a single unit — up to 15A per output.

4
Control Outlets
15A
Max Output per Outlet
1x DST, 1x DSH, 2x DSP
Outlet Configuration
RJ12
Controller Connection

What the 4RS-2 Does

The TrolMaster 4RS-2 is a pre-configured, 4-outlet device station kit engineered specifically for the TrolMaster Tent-X environmental control system. It connects to the Tent-X controller via standard RJ12 cable and occupies 4 device module slots on the controller. Once addressed, each outlet is independently managed by the Tent-X according to its assigned function — temperature response, humidity response, or programmed timer scheduling.

The kit ships with outlets pre-assigned left to right: one DST outlet for temperature-controlled devices (heaters, coolers, AC units), one DSH outlet for humidity-controlled devices (humidifiers, dehumidifiers), and two DSP outlets for time-programmed devices such as supplemental lighting, pumps, or fans. The power cable plugs directly into a standard wall socket — no junction box wiring required.

Who This Kit Is For

The 4RS-2 is the right choice for licensed cannabis and hemp operators running TrolMaster Tent-X controllers who need to expand device control without adding individual standalone modules for every piece of equipment. Instead of purchasing and addressing separate DST, DSH, and DSP stations one at a time, this kit bundles all four into a single unit that installs in minutes.

It fits operators building out single-zone cultivation spaces — including tightly managed canopy rooms, dedicated propagation areas, and micro-grow environments — where the Tent-X serves as the central automation hub. If your facility uses the Tent-X and you're adding or replacing environmental control hardware, the 4RS-2 is the most efficient way to bring temperature, humidity, and programmable device control online simultaneously.

Key Features and Outlet Functions

Each of the four outlets is independently addressable and rated at up to 15A, allowing operators to run high-draw equipment on any channel without requiring additional relay stations for typical load ranges. The DST outlet responds to temperature set points programmed in the Tent-X, switching the connected device on or off to hold the target temperature range. The DSH outlet manages humidity devices the same way — triggering humidifiers or dehumidifiers based on set-point thresholds in the controller.

The two DSP outlets function as programmable timer channels. Any device that needs to run on a defined schedule — supplemental lighting circuits, irrigation pumps, CO2 controllers, or ancillary fans — can be wired into a DSP port and managed entirely through the Tent-X's scheduling interface or the TM+ Pro mobile app. All four outlets share a direct power connection to the wall socket, simplifying the electrical footprint inside the grow room.

Integration with the TrolMaster Tent-X Ecosystem

The Tent-X controller supports connection of up to four DS-type plug-in control modules and up to 16 temperature, humidity, and program devices across the system. The 4RS-2 uses 4 of those device module slots in one clean installation, making it an efficient expansion choice when commissioning a new zone or retrofitting an existing one. Because it connects via plug-and-play RJ12 cable, no special tools or electrician access is required to address the unit.

Operators managing their Tent-X through the TrolMaster TM+ Pro app retain full remote control over all four outlets — including set-point adjustments, scheduling changes, and real-time status monitoring — after the 4RS-2 is addressed. For facilities standardizing on the TrolMaster ecosystem across multiple zones or build-outs, the 4RS-2 provides consistent, auditable device control architecture from zone to zone. Contact HSC to discuss fit within your current or planned TrolMaster setup.

Specifications

SKU4RS-2
Compatible ControllerTrolMaster Tent-X (TCS-1)
Number of Outlets4
Outlet Configuration1x DST (temperature), 1x DSH (humidity), 2x DSP (timer/program)
Max Output per Outlet15A
Controller ConnectionRJ12 cable (plug-and-play)
Device Module Slots Used4 (on Tent-X controller)
Power ConnectionDirect wall socket (integrated power cable)
Input Voltage (DST/DSH/DSP modules)100–240 VAC, 50/60 Hz
Working Environment32–122°F (0–50°C), Humidity ≤90%

Frequently Asked Questions

Is the 4RS-2 compatible with TrolMaster controllers other than the Tent-X?

The 4RS-2 is designed specifically for the TrolMaster Tent-X (TCS-1) controller. Individual DST, DSH, and DSP modules in the standalone form factor are compatible with other TrolMaster systems such as the Hydro-X. If you're running a Hydro-X or Carbon-X system, contact HSC and we'll identify the correct device station configuration for your setup.

Can I run a dehumidifier and a heater off this kit at the same time?

Yes. The DST outlet handles temperature-triggered devices such as heaters and cooling units, while the DSH outlet manages humidity-triggered devices like dehumidifiers and humidifiers. Both can operate simultaneously and independently under their respective Tent-X set points. Verify the amperage draw of your connected equipment stays within the 15A per-outlet rating.

What types of devices can I plug into the DSP (timer) outlets?

The DSP outlets are programmable timer channels — any device that needs to run on a fixed or scheduled on/off cycle can be connected: supplemental lighting circuits, irrigation or fertigation pumps, CO2 equipment, auxiliary fans, or other ancillary devices. Scheduling is configured directly through the Tent-X controller interface or the TrolMaster TM+ Pro app.

How many device module slots does the 4RS-2 use on the Tent-X?

The 4RS-2 occupies 4 device module slots on the Tent-X controller — one slot per outlet. The Tent-X supports connection of up to 4 DS-type plug-in modules, so the 4RS-2 kit fills that capacity in a single, pre-configured unit.

How do I get pricing and availability through HSC?

HSC supplies TrolMaster equipment nationally to licensed cannabis and hemp operators. Use the Request a Quote button on this page or contact us directly. We'll confirm availability, lead time, and wholesale pricing through our direct account with TrolMaster.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.