Audible + visual CO2 alarm with LCD ppm readout for the TrolMaster Carbon-X system.
The TrolMaster AS-4 is an audible-visual CO2 alarm station featuring a blue LED strobe indicator and an LCD digital ppm display — designed to mount outside monitored grow rooms and alert personnel to unsafe CO2 concentrations in real time.
The TrolMaster AS-4 is an audible-visual alarm module within the Carbon-X CO2 safety and monitoring ecosystem. It combines a high-visibility blue LED strobe with an LCD screen that shows live CO2 ppm readings, giving anyone approaching a grow room immediate, at-a-glance awareness of atmospheric CO2 conditions. The unit is purpose-built to mount outside the monitored space — on corridor walls, above entry doors, or in hallways adjacent to cultivation rooms — so staff can assess conditions before entering. When CO2 levels exceed the threshold set in the Carbon-X main controller (CDA-1), the AS-4 simultaneously sounds its audible alarm and begins blinking the blue LED indicator, providing both audio and visible notification that conditions inside the room require attention.
The AS-4 is a fit for any licensed indoor cannabis or hemp operation that uses supplemental CO2 enrichment and needs to satisfy local or state safety regulations governing CO2 monitoring and alarming. Multi-room facilities — whether single-site vertical grows, multi-suite licensed producers, or multi-building campuses — benefit most, since the Carbon-X system supports up to 13 separately monitored zones and up to 40 total output device stations. Operators building out new facilities, adding canopy, or going through state compliance inspections will find the AS-4 a required component for any room in their Carbon-X build-out. Facility managers spec-ing alarm colors to meet jurisdiction-specific fire or safety code requirements should note the Carbon-X alarm station line is available in multiple indicator colors (blue, orange, mixed); the AS-4 covers the blue requirement.
Blue LED indicator: The blue LED display indicator activates — strobing — when the CO2 level exceeds the user-configured limit in the CDA-1 controller, providing a visually distinct warning that is identifiable from a distance and can be matched to site-specific color-coding requirements.
LCD digital ppm readout: The station continuously displays the current CO2 ppm level on its LCD screen, not just alarm state — so staff walking the floor can check levels without accessing a controller panel or app.
Dual-sensor linkage for redundancy: The AS-4 can be linked to either the AL-1 or AL-2 CO2 sensor channel on the Carbon-X controller, or linked to both sensor channels simultaneously for full redundancy — ensuring the alarm fires on a fault in either sensor without requiring two separate alarm stations.
RJ12 plug-and-play connection: Like all Carbon-X modules, the AS-4 connects via standard RJ12 cable. The included 16 ft RJ12 cable provides immediate installation reach. Note: the AS-4 requires the SPH-1 Splitter Hub for supplemental power delivery over the RJ12 line — the SPH-1 eliminates the need for a separate power source at each alarm station.
The Carbon-X system is a modular CO2 safety architecture centered on the CDA-1 main controller. Each monitored zone requires at minimum one CO2 sensor (MBS-K30) and one audio-visual alarm station. The AS-4 fills the alarm-station role for zones where blue is the required or preferred indicator color. All alarm stations, including the AS-4, must be connected through a powered SPH-1 Splitter Hub — the hub delivers power over the shared RJ12 communications cable, keeping installation clean with no per-device power wiring. The system supports both high-level (up to 30,000 ppm) and low-level (5,000 ppm) alert thresholds, both user-adjustable to match local regulations. When the Carbon-X detects an exceedance, it can simultaneously trigger alarm stations like the AS-4, activate ventilation via the DSC-1, shut the main CO2 solenoid via the DSE-1, and send a dry contact signal to a facility fire alarm panel via the DSD-1 — all from a single event trigger. Remote monitoring and push notifications are also available through the TrolMaster mobile app with internet connectivity enabled on the CDA-1.
| SKU | AS-4 |
| Brand | TrolMaster |
| System Compatibility | TrolMaster Carbon-X (CDA-1) |
| Alarm Type | Audible + Blue LED visual strobe |
| Display | LCD digital CO2 ppm readout |
| Sensor Channel Linkage | AL-1, AL-2, or both (dual-channel redundancy) |
| Connection | RJ12 (requires SPH-1 Splitter Hub for power) |
| Included Cable | 16 ft RJ12 cable |
| Operating Temperature | 32–122 °F (0–50 °C) |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Package Dimensions | 130 mm (L) × 187 mm (W) × 88 mm (H) |
| Warranty | 3-year manufacturer warranty (normal operating conditions) |
The AS-4 is a Carbon-X system module — it requires the TrolMaster CDA-1 Carbon-X main controller. The alarm threshold is configured in the CDA-1, which then triggers the AS-4 when CO2 levels exceed the set limit. It is not designed to operate independently without the Carbon-X system.
The AS-4 draws power through the RJ12 communications cable. The SPH-1 is a powered hub that injects power into the RJ12 line, allowing the alarm station to operate without a dedicated power supply wired to each unit. This keeps installation clean and scalable across multi-room builds. The SPH-1 is sold separately.
The AS-4 can be linked to both the AL-1 and AL-2 sensor channels on the Carbon-X simultaneously, providing redundancy — if either sensor detects an exceedance, the AS-4 will alarm. However, for separate physical zones each requiring their own exterior-mounted alarm, a separate AS-4 (or other alarm station) per zone is required. The Carbon-X supports up to 13 monitoring zones and up to 40 total device stations.
The hardware functionality is identical — audible alarm, LED strobe, LCD ppm display, RJ12 connection. The only difference is the LED indicator color: the AS-3 has an orange indicator and the AS-4 has a blue indicator. Color selection is typically driven by jurisdiction-specific fire safety or CO2 alarm code requirements.
The LCD display shows the live digital CO2 ppm reading continuously — not just during an alarm. This allows facility staff to monitor ambient CO2 levels from outside a room at any time without needing to check the CDA-1 controller panel or the TrolMaster app.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote