Trolmaster Available

CO2 Alarm Station (audio/visual) with cable set

Audio/visual CO2 alarm module for commercial grow rooms — Carbon-X system compatible.

The TrolMaster Carbon-X AS-1 CO2 Alarm Station is an audio/visual alarm unit designed to alert personnel when CO2 levels exceed safe thresholds inside or outside any monitored grow room. Includes the DSD-1 dry contact station, AS-5 audible-visual alarm module, and cable set — everything needed to integrate a per-room safety alarm into a Carbon-X deployment.

100–240 VAC, 50/60 Hz
Input Voltage
DSD-1 + AS-5 + Cable Set
Kit Includes
30 VDC / 250 VAC, 6 A
Dry Contact Rating
0–50 °C / ≤ 90% RH
Operating Environment

What the AS-1 Is

The AS-1 is TrolMaster's entry-level audio/visual alarm station for the Carbon-X multi-zone CO2 safety system. The kit bundles the DSD-1 dry contact station and the AS-5 audible-visual alarm module with the cable set required for connection to the Carbon-X controller (CDA-1). The unit is rated for universal input voltage (100–240 VAC), so it installs cleanly in any commercial facility without voltage conversion.

When CO2 concentration in the monitored space climbs above the configured high-level threshold — or drops below the configured low-level threshold — the AS-1 triggers both an audible tone and a visible strobe/light, immediately alerting anyone in or near the room. The dry contact output (rated 30 VDC / 250 VAC, 6 A) can also be wired into a facility fire alarm panel, enabling full integration with a building's existing life-safety infrastructure.

Who Needs It and Where It Fits

Any licensed cannabis or hemp facility running supplemental CO2 enrichment faces two distinct risks: elevated CO2 from enrichment equipment malfunctions, and depleted CO2 that goes undetected. Regulators in most states require per-room audio/visual alarm coverage where supplemental CO2 is used. The AS-1 is purpose-built to satisfy that requirement as part of the Carbon-X platform.

The Carbon-X system is designed to monitor up to 13 separate zones, with up to 40 total output devices across the build. The AS-1 occupies one of those output slots per room. Facilities with multiple flower rooms, veg rooms, or mother rooms will typically deploy one AS-1 per space, all reporting back to a single CDA-1 controller. The modular architecture means you can start with one room and expand the alarm network without replacing any hardware.

Key Features

Dual-threshold monitoring: the Carbon-X system supports both high-level alerts (up to 30,000 ppm) and low-level alerts (floor of 5,000 ppm), and both limits are user-adjustable on the CDA-1 controller to align with local and state regulatory requirements. The AS-1 can be linked to the AL-1 channel, the AL-2 channel, or both simultaneously for full redundancy — ensuring no single sensor failure creates a blind spot.

The DSD-1 dry contact output included in the AS-1 kit provides N/O and N/C connections, enabling direct interface to a facility fire alarm panel. This allows the Carbon-X event to trigger a building-wide response — not just the local strobe — without additional relay hardware. The plug-and-play cable set simplifies commissioning: connect to the CDA-1's RJ12 device port, configure the sensor channel assignment, and the station is live.

Remote monitoring is handled through the TrolMaster app, which can push notifications and alert emails when the AS-1's threshold is breached. This gives facility managers and compliance officers real-time visibility without being on-site, supporting both operational response and documentation for regulatory audits.

How It Fits a Commercial Build

In a multi-room facility, the recommended deployment is one AS-1 per monitored room, mounted at a height appropriate for CO2 detection (CO2 is heavier than air, so lower-wall or mid-wall placement is typical for high-level detection). The unit can be mounted inside or outside the grow room, which gives safety-conscious operators the option to alert corridor personnel without opening the room door.

For facilities integrating the full Carbon-X stack — CDA-1 controller, MBS-K30 CO2 sensors, DSE-1 emergency stop station, DSC-1 ventilation control, and DSD-1 fire panel interface — the AS-1 completes the per-room alarm layer. Operators who are early in a Carbon-X buildout can add AS-1 stations zone by zone as canopy expands, without reconfiguring the controller. Contact HSC to spec the right number of alarm stations for your facility's zone count and floor plan.

Specifications

SKUAS-1
BrandTrolMaster
Product LineCarbon-X CO2 Safety System
Kit ContentsDSD-1 Dry Contact Station, AS-5 Audible-Visual Alarm, Cable Set
Input Voltage100–240 VAC, 50/60 Hz
Output Current24 V, 0.2 A
Dry Contact Output Rating30 VDC / 250 VAC, 6 A
Operating Temperature0–50 °C
Operating Humidity≤ 90% RH (non-condensing)
Package Dimensions160 mm × 80 mm × 90 mm

Frequently Asked Questions

Does the AS-1 work as a standalone CO2 alarm, or does it require the full Carbon-X system?

The AS-1 is designed to operate as part of the TrolMaster Carbon-X system. It connects to the CDA-1 controller via the RJ12 device port and receives its trigger signal from the CO2 sensors registered to that controller. It is not a standalone detector — you need at least a CDA-1 and one CO2 sensor (such as the MBS-K30) in the system for the AS-1 to function.

Can the AS-1 be linked to both the high-level and low-level CO2 sensor channels?

Yes. The AS-1 can be linked to either the AL-1 or AL-2 sensor channel on the CDA-1, or to both channels simultaneously for complete redundancy. This means a single alarm station can cover both an enrichment-induced high-CO2 event and a low-CO2 equipment fault within the same room.

Can the AS-1 integrate with our facility's existing fire alarm panel?

Yes. The included DSD-1 dry contact station provides both N/O and N/C connections rated at 30 VDC / 250 VAC, 6 A, and is designed to interface directly with a building fire alarm panel. This allows a Carbon-X CO2 event to trigger a facility-wide response through your existing life-safety infrastructure.

Where should the AS-1 be physically mounted — inside or outside the grow room?

The AS-1 can be mounted either inside or outside the grow room. Mounting outside the room allows corridor personnel and facility staff to see and hear the alarm without entering the affected space, which is a practical safety advantage in facilities with controlled-access rooms. Mounting inside is also supported and may be required by some local codes — confirm placement with your AHJ.

How many AS-1 stations can be connected to a single Carbon-X system?

The Carbon-X system supports up to 40 total output devices across the build, with the CDA-1 capable of monitoring up to 13 separate zones. Each AS-1 occupies one output slot. In practice, one AS-1 per monitored room is the standard deployment. Contact HSC to confirm the right configuration for your zone count.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.