Amber-light audible-visual CO2 alarm for corridor and hallway mounting outside enriched grow zones.
The TrolMaster AS-3 CO2 Alarm Station is an audible-visual module designed to mount outside CO2-enriched grow rooms, displaying live ppm levels and triggering a 100 dB alarm plus blinking amber LED whenever concentrations exceed the threshold set on the Carbon-X main controller. Part of TrolMaster's modular Carbon-X CO2 safety ecosystem.
The TrolMaster AS-3 is an audible-visual alarm module built specifically for facilities that use supplemental CO2. It mounts outside the grow room or cultivation zone — on a corridor wall, hallway, or entry point — where staff can read CO2 ppm levels on the LCD display without entering the space. When CO2 concentrations climb above the threshold programmed into the Carbon-X main controller (CDA-1), the AS-3 triggers simultaneously: a 100 dB audible siren and a blinking amber LED indicator. At that sound pressure level, the alarm cuts through HVAC noise and busy facility floors.
The amber indicator color is the distinguishing spec here. The Carbon-X alarm station lineup includes multiple indicator colors to meet different facility and fire-code requirements, and the AS-3's amber light is the appropriate choice for certain local regulatory frameworks. Confirm your jurisdiction's visual alarm color requirements when specifying.
The AS-3 is a peripheral output device within TrolMaster's Carbon-X CO2 safety platform. The Carbon-X system (built around the CDA-1 main controller) monitors CO2 ppm across up to 13 separate zones, supports both high-level alerts (up to 30,000 ppm) and low-level alerts (down to 5,000 ppm), and can trigger a range of automated responses — CO2 solenoid shutoff, ventilation fan actuation, damper control, and fire alarm panel interface — in addition to audio-visual alarms like the AS-3.
The AS-3 connects to the CDA-1 via standard RJ12 cable (a 16 ft RJ12 cable is included in the box) and requires the SPH-1 powered splitter hub for supplemental power — the SPH-1 is a separate line item and must be included in any complete station build. The AS-3 can be linked to either the AL-1 or AL-2 sensor channel, or both simultaneously, giving full sensor redundancy at that alarm point. Up to 40 device stations can run on a single Carbon-X system, so multi-room operators can scale alarm coverage across an entire facility from one controller.
Any licensed cannabis or hemp cultivation facility running supplemental CO2 enrichment needs compliant audio-visual alarms at room egress points — this is not optional in most state-level cannabis regulations and aligns with OSHA general industry standards for CO2 hazard notification. The AS-3 is the right fit when: (1) you are building on an existing Carbon-X CO2 safety install and need additional alarm stations for new rooms or zones; (2) your AHJ or state cannabis regulator specifies amber as the required visual alarm color for high-CO2 zones; or (3) you want an alarm module that also shows live ppm readout at the door, not just a light and siren.
The LCD ppm display is particularly useful for cultivation staff doing room entry checks — rather than relying solely on a sensor app or controller screen located elsewhere in the facility, staff can read the actual CO2 concentration directly at the room door before deciding whether entry is safe. This is a meaningful workflow advantage in facilities with multiple rooms running different CO2 setpoints.
Installation is plug-and-go via RJ12 — no low-voltage wiring expertise required. Mount the AS-3 outside the room to be monitored at a height readable by staff. Run the included 16 ft RJ12 cable to the SPH-1 splitter hub; the SPH-1 then connects upstream to the CDA-1 controller. All alarm threshold settings are managed at the CDA-1 level — the AS-3 itself has no independent threshold programming. The CDA-1 supports remote monitoring and push-alert notifications via the TrolMaster smartphone app over Wi-Fi or LAN (Cat 5/6 to router), so operators can receive CO2 alerts remotely even when off-site.
Operating environment spec: 32–122°F temperature range, up to 90% relative humidity — suitable for the ambient conditions typical outside a sealed grow room. Plan your SPH-1 placement to keep cable runs within spec, and use TrolMaster's RJ12 extension cable sets (ECS-1 or ECS-500 cable roll) for longer runs. HSC supplies the full Carbon-X ecosystem — CDA-1 controller, sensors, splitter hubs, alarm stations, and cabling — so you can quote the complete safety install through a single account.
| SKU | AS-3 |
| Alarm Type | Audible + Visual (simultaneous) |
| Indicator Color | Amber LED |
| Display | LCD digital CO2 ppm level readout |
| Audible Alarm Level | 100 dB |
| Sensor Channel Compatibility | AL-1 and/or AL-2 (Carbon-X system) |
| Power | Via SPH-1 powered splitter hub (required, sold separately) |
| Connection | RJ12 (16 ft RJ12 cable included) |
| Operating Temperature | 32–122°F (0–50°C) |
| Operating Humidity | Up to 90% RH |
| Package Dimensions | 130mm L × 187mm W × 88mm H |
| Gross Weight | 1.26 lbs (0.57 kg) |
The AS-3 requires the Carbon-X CDA-1 main controller to function — it is not a standalone detector. The CDA-1 reads CO2 data from the connected sensors (MBS-K30 or equivalent on the AL-1/AL-2 channels) and instructs the AS-3 when to trigger. You will also need the SPH-1 powered splitter hub to power the AS-3. It cannot operate independently without those system components.
The Carbon-X alarm station lineup is available in multiple indicator colors — amber (AS-3), and other colors across the range — to meet varying local fire code and regulatory requirements for visual alarm identification in CO2 hazard zones. The functional specs (audible alarm, LCD ppm display, RJ12 connection) are the same across stations; indicator color is the differentiating factor. Check your state cannabis regulations and AHJ requirements to confirm which color is required for your facility.
A single AS-3 can be linked to the AL-1 sensor channel, the AL-2 sensor channel, or both simultaneously for redundancy. However, it is an alarm output for the zone where it is mounted. For multi-room facilities, each monitored area needs its own alarm station. The Carbon-X system supports up to 40 total device stations across the install, so multi-room builds are well within the platform's capacity.
Yes. The LCD display shows the live CO2 ppm reading continuously, regardless of whether an alarm condition is active. This allows staff to monitor the concentration at the room entry point at any time — not only when an alarm is triggered. The amber LED and audible alarm only activate when CO2 exceeds the threshold set on the CDA-1 controller.
Yes. HSC carries the complete TrolMaster Carbon-X ecosystem. Whether you are speccing a single-zone install or a multi-room build across an entire cultivation facility, request a quote and we will put together a complete line-item breakdown for the full safety system.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.
Request a Quote