Apera Available

Benchtop Lab pH Meter for Micro-volume (>15 micro liters) Water Solution Samples and/or Biological Samples

Lab-grade pH for the smallest samples — down to 15 µL, built for biological and nutrient work.

The Apera Instruments PH700-MS (AI5017) is a benchtop pH meter purpose-built for micro-volume water solutions, biological fluids, and protein-containing samples. Equipped with the Swiss-engineered LabSen 241-3SP electrode, it delivers ±0.01 pH accuracy with a minimum sample volume as low as 15 microliters — giving your lab team precise data without burning through valuable extract or tissue material.

±0.01 pH
Accuracy
≥15 µL (with micro container)
Min. Sample Volume
0–14.00 pH
Measurement Range
IP54
Ingress Protection

What It Is

The Apera PH700-MS is a dedicated benchtop pH and temperature meter from Apera's 700-series lab lineup. Where a standard benchtop meter requires a conventional dip volume, the PH700-MS pairs the PH700 meter body with the LabSen 241-3SP — a Swiss-technology glass micro-electrode engineered specifically for micro-volume water solutions, biological matrices, and protein-containing liquids such as serum or microbiological samples.

The LabSen 241-3SP uses a micro cylindrical glass membrane (3 mm tip, 4 mm stainless steel shaft) and Protelyte electrolyte — a specialized oily reference solution formulated for protein-laden samples that would clog or contaminate a standard gel-filled reference junction. A long-life reference system built from a glass tube, AgCl, and a reference silver wire maintains junction stability over an extended service life. With the optional ultra-micro container, the minimum testable volume reaches 15 microliters — a critical capability when sample material is limited and repeat testing is not an option.

Who It's For

Commercial cannabis and hemp operations running in-house tissue testing, extract QC, or nutrient formulation work generate small, high-value samples that standard electrodes simply can't handle efficiently. The PH700-MS is built for exactly that environment: a regulated lab bench where volume is scarce, accuracy is non-negotiable, and downtime between tests needs to be minimal.

It's equally relevant for operations that want to verify pH on small-batch nutrient mixes, enzyme or protein-containing additives, or biological inoculants before they hit the reservoir or substrate. If your compliance or quality program calls for documented, logged pH verification at the lab level — rather than a handheld pen at the fertigation skid — this meter gives you the data traceability and measurement precision to back it up.

Key Features

Calibration runs 1–3 points automatically with self-diagnosis and electrode condition display, so technicians can confirm the electrode is performing before recording a result. The meter supports pre-mixed buffer solutions at pH 4.00, 7.00, and 10.01 (included in the kit). Automatic temperature compensation spans 0–100°C, keeping readings reliable across sample temperatures. Max/Min reading mode lets you track peak and minimum values over a measurement period without manually watching the display.

The PH700-MS stores up to 50 data sets internally — enough for a full day of discrete sample events without connecting to a PC. The housing carries an IP54 rating: splash-proof and dust-proof, suited to bench environments where nutrient concentrates, solvents, or moisture are a daily reality. BNC electrode connectivity means the LabSen 241-3SP is interchangeable with other Apera BNC-compatible electrodes if your testing protocol expands. The kit ships with a dual-electrode holder (accommodates up to two electrodes simultaneously), three 50 mL bottles of pre-mixed calibration solutions, and everything needed to start measuring on day one.

How It Fits a Commercial Grow Lab Build

Most cultivation facilities that run a dedicated lab station already have a general-purpose benchtop meter for fertigation QC. The PH700-MS fills the gap that meter leaves: small-volume biological or protein-containing samples where a standard electrode produces unstable readings or requires more material than you can spare. Think post-extraction pH verification, tissue culture prep, enzyme-based additive confirmation, or small-batch R&D formulations.

The two-year instrument warranty and six-month electrode warranty align with the calibration cycle expectations of a compliance-tracked lab. When the LabSen 241-3SP electrode reaches end of service life, it's a field-replaceable BNC unit — you replace the probe, not the meter body. For facilities scaling their quality programs or preparing for state-level testing audits, having a dedicated micro-volume benchtop meter in the log creates a clear chain of measurement documentation that a handheld simply cannot provide.

Specifications

Model / SKUApera PH700-MS / AI5017
Electrode IncludedLabSen 241-3SP pH/Temp. (Swiss sensor technology)
pH Measurement Range0–14.00 pH
pH Accuracy±0.01 pH
pH Resolution0.01 pH
Minimum Sample Volume≥15 µL (with ultra-micro container); ≥30 µL standard
Temperature CompensationAutomatic, 0–100°C
Calibration1–3 point auto-calibration; buffers pH 4.00 / 7.00 / 10.01
Data Storage50 data sets
Ingress ProtectionIP54 (spill-proof and dust-proof)
Electrode ConnectorBNC
Kit IncludesMeter, LabSen 241-3SP electrode, dual electrode holder, 3×50 mL pre-mixed calibration solutions (pH 4/7/10)

Frequently Asked Questions

What makes the LabSen 241-3SP different from a standard combination pH electrode?

The LabSen 241-3SP uses a micro cylindrical glass membrane (3 mm tip) and Protelyte electrolyte — a specialized oily reference solution formulated for protein-containing and viscous samples. Standard gel-filled electrodes can clog or produce unstable readings in biological matrices; the 241-3SP's reference system is engineered to stay stable in those environments. The stainless steel protective shaft also protects the slim glass tube from mechanical damage.

Can this meter test samples smaller than 30 microliters?

Yes, with the optional ultra-micro container (sold separately). The LabSen 241-3SP can measure down to 15 microliters when used with that accessory. Without it, the minimum recommended volume is approximately 30 microliters.

Does the electrode have a built-in temperature sensor?

The LabSen 241-3SP includes temperature measurement capability (it is listed as a pH/Temp. electrode in this kit configuration), enabling automatic temperature compensation across 0–100°C without a separate probe. Automatic temperature compensation is active as long as the electrode is properly connected.

How many calibration points does the PH700-MS support, and which buffers?

The meter supports 1–3 point automatic calibration. Pre-mixed calibration solutions at pH 4.00, 7.00, and 10.01 are included in the kit (50 mL each). The self-diagnosis function and electrode condition display let you verify electrode health before each calibration session.

Is the PH700-MS suitable for compliance-level documentation in a licensed facility lab?

The meter stores up to 50 data sets internally and features a Max/Min reading mode for tracking measurement ranges over time. For facilities requiring a paper or digital log, data can be recorded from the on-board storage. The ±0.01 pH accuracy and traceable auto-calibration with electrode condition display support the documentation rigor expected in licensed cannabis lab environments. If your SOP requires USB data export, review the PH800-series meters in the Apera lineup for GLP data management functionality.

Ready to spec this for your facility?

Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.

Request a Quote