25A high-current relay module for TrolMaster Hydro-X, Aqua-X, Carbon-X, and Green-X systems.
The TrolMaster DSR-1 is a 25-amp, 100–277V relay device station designed to extend TrolMaster control systems to high-current loads. Configurable as a temperature, humidity, CO₂, or timer output module — with overload protection and local override built in.
The TrolMaster DSR-1 is a high-current relay device station that slots into the modular TrolMaster ecosystem as a controllable output point for loads up to 25 amps across a 100–277V range. Where standard device stations top out at 10A on 120V, the DSR-1 handles the heavier equipment loads common in commercial builds — dehumidifiers, contactors, fans, CO₂ solenoids, and lighting circuits — without requiring a separate relay panel.
It connects via RJ12 to the Devices port on compatible TrolMaster controllers and is addressed and assigned a function through the controller's interface. No custom wiring harnesses, no proprietary connectors outside the standard TrolMaster RJ12 topology. Plug in, address the station, assign a mode, and the controller owns that load.
The DSR-1 is the right station when you need the controller to switch a load that exceeds the 10A capacity of a standard device station, or when you're running 240V or 277V equipment — voltage ranges unsupported by the lower-tier stations. Commercial cultivation facilities running double-ended HID lighting contactors, high-amperage dehumidifiers, or multi-ton HVAC units benefit most from this module.
Facilities that have already standardized on TrolMaster controllers (Hydro-X, Hydro-X Pro, Aqua-X, Carbon-X, or Green-X) and are expanding room count or device count will reach for the DSR-1 when their existing device stations can't handle the amperage or voltage of new equipment being added to the build.
The DSR-1 supports four configurable operating modes — temperature (DST), humidity (DSH), CO₂ (DSC), and timer/program (DSP) — so a single SKU covers the full range of environmental triggers a room requires. Assignment is done at the controller level, not at the hardware level, meaning you can reconfigure an installed station without swapping the unit.
Built-in overload protection guards connected equipment from current spikes. A local override function lets facilities staff manually toggle the relay at the station without going into the controller interface — useful during maintenance windows or sensor calibration. A local alarm activates on relay contact adhesion, flagging a stuck relay before it causes an equipment run-on event. Plug-and-play addressing over RJ12 means no dipswitches, no configuration jumpers.
In a TrolMaster-based grow room, the DSR-1 lives on the Devices bus alongside lower-amperage DS modules and sensor stations. A typical multi-room facility might run one DSR-1 per room to handle the dehumidifier contactor or a 240V lighting circuit, with standard DSP or DSH stations covering lower-current supplemental loads on the same controller.
Because the DSR-1 covers 100–277V at 25A, it operates cleanly on both the 120V and 208/240/277V circuits standard in commercial cultivation spaces — no step-down transformers required. This makes it equally applicable to purpose-built licensed cannabis facilities and converted industrial buildings where panel voltage varies room to room. The included 0.5ft and 4ft RJ12 cables cover most cabinet and panel mount configurations out of the box.
| SKU | DSR-1 |
| Input Voltage | 100–277V~, 50/60Hz |
| Output Voltage | 100–277V~, 50/60Hz |
| Output Current | 25A |
| Operating Temperature | 32–104°F (0–40°C) |
| Operating Humidity | ≤90% RH |
| Configurable Modes | DST (temp), DSH (humidity), DSC (CO₂), DSP (timer) |
| Connection Interface | RJ12 |
| Compatible Systems | Hydro-X, Aqua-X, Carbon-X, Green-X |
| Included Cables | 1× 0.5ft RJ12, 1× 4ft RJ12 |
The DSR-1 is rated for 25A at 100–277V, making it suitable for high-current and high-voltage loads. Standard stations like the DSP-1 are rated for 10A at 100–240V. Use the DSR-1 when the load exceeds 10A or operates on a 277V circuit.
The DSR-1 works with TrolMaster's Hydro-X, Hydro-X Pro, Aqua-X, Carbon-X, and Green-X control systems. It connects to the Devices port via standard RJ12 cabling.
Yes. The DSR-1 can be configured as a temperature (DST), humidity (DSH), CO₂ (DSC), or timer/program (DSP) module through the controller interface. Reconfiguration does not require replacing the station.
Yes — it includes overload protection, a local manual override, and a local alarm that triggers on relay contact adhesion (a stuck relay condition). These features are particularly relevant in commercial grows where an uncontrolled run-on event on a dehumidifier or HVAC unit can damage a crop.
Use the Request a Quote button on this page. HSC works directly with TrolMaster and can supply the DSR-1 — along with compatible controllers, sensors, cabling, and the full TrolMaster accessory line — to licensed cannabis and hemp operators nationwide.
Get operator-direct pricing and availability. We supply licensed commercial cultivators nationwide.